文献速递脑血管病外科脊柱脊髓外科

脊髓动静脉畸形与髓内脊髓海绵状血管畸形术中电生理监测结果的差异

Differences in the Electrophysiological Monitoring Results of Spinal Cord Arteriovenous and Intramedullary Spinal Cord Cavernous Malformations.
PubMed 文献 · World Neurosurg · 2018-10-17

本研究纳入2012年11月至2016年1月的109例患者(脊髓动静脉畸形55例、髓内脊髓海绵状血管畸形54例),比较两者术中电生理监测的差异。脊髓动静脉畸形手术监测敏感度77.3%、特异度87.1%,髓内脊髓海绵状血管畸形分别为68.8%和83.3%。作者认为电生理监测可提供有效指导,但脊髓动静脉畸形切除的永久性改变和术后功能障碍更多。

要点

  • 脊髓动静脉畸形术中监测敏感度77.3%、特异度87.1%。
  • 髓内脊髓海绵状血管畸形术中监测敏感度68.8%、特异度83.3%。
  • 脊髓动静脉畸形切除的永久性改变和术后功能障碍多于髓内脊髓海绵状血管畸形。

核心结论

  • 电生理监测在脊髓血管畸形手术中提供有效指导。
  • 脊髓动静脉畸形切除导致的永久性改变和术后功能障碍多于髓内脊髓海绵状血管畸形。
  • 假阳性和假阴性结果的存在提示电生理监测不能完全预测患者的完整功能。

研究设计与样本

  • 研究纳入2012年11月至2016年1月收治的109例患者,其中脊髓动静脉畸形55例、髓内脊髓海绵状血管畸形54例。
  • 所有患者在整个手术过程中接受电生理监测,包括体感诱发电位、运动诱发电位和肌电图。
  • 运动诱发电位预警标准为波幅下降>80%,体感诱发电位预警标准为波幅下降>50%且潜伏期延长>10%。

主要发现

  • 脊髓动静脉畸形手术术中监测的敏感度为77.3%、特异度为87.1%。
  • 髓内脊髓海绵状血管畸形手术术中监测的敏感度为68.8%、特异度为83.3%。
  • 脊髓动静脉畸形组21例出现永久性改变,其中17例术后即刻功能障碍、8例出院前恢复、5例远期随访时存在神经功能缺损。
  • 髓内脊髓海绵状血管畸形组17例出现永久性改变,其中11例术后即刻功能障碍、5例出院前恢复、2例远期残留神经功能缺损。

关键数值与推荐

  • 运动诱发电位预警标准:波幅下降>80%。
  • 体感诱发电位预警标准:波幅下降>50%且潜伏期延长>10%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Spinal arteriovenous malformations (SAVMs) and intramedullary spinal cord cavernous malformations (ISCCMs) have a very low incidence of disease. The purpose of this study was to compare the differences in electrophysiologic monitoring in these 2 surgeries. METHODS: The study included 109 patients (SAVMs, n = 55; ISCCMs, n = 54) recruited from November 2012 to January 2016. All patients underwent electrophysiologic monitoring during the entire operation, including somatosensory-evoked potentials, motor-evoked potentials, and electromyography. We used an amplitude reduction of >80% as warning criterion for motor-evoked potentials and an amplitude reduction of more than 50% and latency prolongation of more than 10% as warning criteria for somatosensory-evoked potentials. RESULTS: In our study, the sensitivity and specificity of intraoperative monitoring during SAVM surgery were 77.3% and 87.1%, respectively. The sensitivity and specificity of intraoperative monitoring during ISCCM surgery were 68.8% and 83.3%, respectively. We found that 21 patients with SAVM showed permanent changes, 17 had immediate postoperative impairment, 8 recovered before discharge, and 5 showed neurologic deficits at long-term follow-up. Of the 17 patients with ISCCMs showing permanent changes, 11 had immediate postoperative impairment, 5 recovered before discharge, and 2 had long-term residual neurologic deficits. CONCLUSIONS: Electrophysiological monitoring provides effective guidance during operation on spinal vascular malformations. Electrophysiologic monitoring revealed that surgical resection of SAVMs resulted in more permanent changes and postoperative dysfunction when compared with ISCCMs. The incidence of both false-positive and -negative results suggests that electrophysiologic monitoring cannot fully predict the complete function of the patients.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Li X, Zhang HQ, Ling F, et al. Differences in the Electrophysiological Monitoring Results of Spinal Cord Arteriovenous and Intramedullary Spinal Cord Cavernous Malformations. World Neurosurg. 2018. PMID: 30339909. doi:10.1016/j.wneu.2018.10.032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。