高分辨率定量磁敏感图用于脑深部电刺激术前丘脑底核功能与结构描绘
研究纳入7名健康志愿者和10例回顾性随机选取的帕金森病患者的3-T MRI数据,比较T2加权成像与定量磁敏感图(QSM)对丘脑底核(STN)的显示。高分辨与低分辨QSM均显示更高对比噪声比,QSM提供更高STN内象限对比率并显示T2w不可见的磁敏感梯度。作者结论认为亚毫米QSM可准确描绘STN功能与解剖特征。
要点
- 高分辨与低分辨QSM图像对比噪声比均高于T2w。
- QSM显示STN内象限对比率更高及T2w不可见的磁敏感梯度。
- 3-T MRI亚毫米QSM可准确描绘STN用于DBS靶点定位。
核心结论
- 作者结论认为,在3-T MRI上亚毫米QSM可准确描绘STN的功能和解剖特征以用于DBS靶点定位。
研究设计与样本
- 研究纳入7名健康志愿者,采集T2w和QSM并重建不同分辨率图像,由放射科医师采用5分制评估图像质量与STN解剖特征可见性并计算对比特性。
- 另回顾性随机选取10例接受3-T MRI用于DBS的帕金森病患者,分析STN大小和磁敏感梯度测量。
主要发现
- 高分辨和低分辨QSM图像均观察到更高对比噪声比(CNR)。
- 分辨率间比较显示QSM的CNR改善,而T2w图像未见改善。
- QSM提供STN内更高的象限间对比率(CR),并显示T2w图像不可见的磁敏感源分布梯度。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Faithful depiction of the subthalamic nucleus (STN) is critical for planning deep brain stimulation (DBS) surgery in patients with Parkinson's disease (PD). Quantitative susceptibility mapping (QSM) has been shown to be superior to traditional T2-weighted spin echo imaging (T2w). The aim of the study was to describe submillimeter QSM for preoperative imaging of the STN in planning of DBS. METHODS: Seven healthy volunteers were included in this study. T2w and QSM were obtained for all healthy volunteers, and images of different resolutions were reconstructed. Image quality and visibility of STN anatomical features were analyzed by a radiologist using a 5-point scale, and contrast properties of the STN and surrounding tissue were calculated. Additionally, data from 10 retrospectively and randomly selected PD patients who underwent 3-T MRI for DBS were analyzed for STN size and susceptibility gradient measurements. RESULTS: Higher contrast-to-noise ratio (CNR) values were observed in both high-resolution and low-resolution QSM images. Inter-resolution comparison demonstrated improvement in CNR for QSM, but not for T2w images. QSM provided higher inter-quadrant contrast ratios (CR) within the STN, and depicted a gradient in the distribution of susceptibility sources not visible in T2w images. CONCLUSIONS: For 3-T MRI, submillimeter QSM provides accurate delineation of the functional and anatomical STN features for DBS targeting.
引用
- Dimov AV, Gupta A, Kopell BH, et al. High-resolution QSM for functional and structural depiction of subthalamic nuclei in DBS presurgical mapping. J Neurosurg. 2018. PMID: 30095333. doi:10.3171/2018.3.JNS172145
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。