MRI纹理分析对胶质瘤分级的诊断准确性
这项回顾性研究纳入94例经组织病理学诊断的胶质瘤患者,术前均行3T MRI,于增强T1图像上手动勾画感兴趣区,用基于影像组学的滤波-直方图纹理分析在0-6 mm空间缩放因子下分析直方图参数,并与WHO胶质瘤分级行Spearman相关分析、用ROC曲线计算AUC以区分肿瘤级别。低级别胶质瘤14例、高级别胶质瘤80例;均值、标准差、阳性像素均值、熵和峰度在不同空间缩放滤波下显示级别间显著差异;2 mm精细纹理尺度的均值区分低、高级别胶质瘤最佳,敏感性和特异性分别为93%和86%(AUC 0.90)。
要点
- 2 mm精细纹理尺度的均值区分低、高级别胶质瘤最佳,敏感性93%、特异性86%(AUC 0.90)。
- 均值、标准差、阳性像素均值、熵和峰度在不同空间缩放滤波下显示胶质瘤级别间显著差异。
- 纹理分析可区分高级别与低级别胶质瘤,纹理特征影像组学数据可为胶质瘤提供补充诊断信息。
核心结论
- 定量测量异质性的纹理分析可区分高级别与低级别胶质瘤。
- 纹理特征影像组学数据可为胶质瘤提供补充诊断信息。
研究设计与样本
- 回顾性研究,纳入经组织病理学诊断的胶质瘤且行术前3T MRI成像的患者,共94例。
- 于增强后T1图像上手动勾画感兴趣区,使用市售研究软件行纹理分析,在0至6 mm空间缩放因子下分析直方图参数。
主要发现
- 94例中低级别胶质瘤14例、高级别胶质瘤80例。
- 均值、标准差、阳性像素均值、熵和峰度在不同空间缩放滤波下显示胶质瘤级别间显著差异。
- 2 mm精细纹理尺度的均值区分低、高级别胶质瘤最佳,敏感性和特异性分别为93%和86%(AUC 0.90)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Texture analysis (TA) can quantify variations in surface intensity or patterns, including some that are imperceptible to the human visual system. The purpose of this study was to determine the diagnostic accuracy of radiomic based filtration-histogram TA to differentiate high-grade from low-grade gliomas by assessing tumor heterogeneity. METHODS: Patients with a histopathological diagnosis of glioma and preoperative 3T MRI imaging were included in this retrospective study. A region of interest was manually delineated on post-contrast T1 images. TA was performed using commercially available research software. The histogram parameters including mean, standard deviation, entropy, mean of the positive pixels, skewness, and kurtosis were analyzed at spatial scaling factors ranging from 0 to 6 mm. The parameters were correlated with WHO glioma grade using Spearman correlation. Areas under the curve (AUC) were calculated using ROC curve analysis to distinguish tumor grades. RESULTS: Of a total of 94 patients, 14 had low-grade gliomas and 80 had high-grade gliomas. Mean, SD, MPP, entropy and kurtosis each showed significant differences between glioma grades for different spatial scaling filters. Low and high-grade gliomas were best-discriminated using mean of 2 mm fine texture scale, with a sensitivity and specificity of 93% and 86% (AUC of 0.90). CONCLUSIONS: Quantitative measurement of heterogeneity using TA can discriminate high versus low-grade gliomas. Radiomic data of texture features can provide complementary diagnostic information for gliomas.
引用
- Ditmer A, Zhang B, Shujaat T, et al. Diagnostic accuracy of MRI texture analysis for grading gliomas. J Neurooncol. 2018. PMID: 30145731. doi:10.1007/s11060-018-2984-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。