文献速递脑血管病外科

对侧经大脑镰入路与同侧前纵裂入路切除中线动静脉畸形的外科与解剖学评估

Contralateral Transfalcine Versus Ipsilateral Anterior Interhemispheric Approach for Midline Arteriovenous Malformations: Surgical and Anatomical Assessment.
PubMed 文献 · World Neurosurg · 2018-08-23

本研究在10例标本上双侧模拟对侧前纵裂入路(CAIA)与同侧前纵裂入路(IAIA)切除中线额顶动静脉畸形(AVM),用立体定向导航比较手术窗、手术自由度与攻击角。结果示深部纵裂内CAIA在AVM下方面攻击角增宽77%(P<0.01),引流静脉、同侧及对侧大脑前动脉手术自由度分别增加54%(P=0.01)、98%(P=0.02)、117%(P<0.01),而浅表区域两种入路无客观差异。

要点

  • 深部纵裂内CAIA在AVM下方面攻击角较IAIA增宽77%(P<0.01)。
  • CAIA对引流静脉、同侧及对侧大脑前动脉手术自由度分别增加54%、98%、117%。
  • 浅表区域两种入路手术窗、目标暴露与手术自由度相似,无客观差异。

核心结论

  • 本研究提示CAIA切除深部中线AVM具有技术优势。
  • 模型浅表区域未见客观差异,提示IAIA是浅表AVM更安全的选择。
  • 结果为后续比较两种入路的临床分析奠定基础。

研究设计与样本

  • 在10例标本上双侧实施CAIA与IAIA,设计两个模型模拟中线AVM最常见特征。
  • 用立体定向导航独立评估手术窗、手术自由度、目标暴露与攻击角,并以Student t检验比较,显著性阈值设为0.05。

主要发现

  • CAIA与IAIA在AVM上方面的手术窗、目标暴露与手术自由度相似。
  • 深部纵裂内CAIA在AVM下方面攻击角较IAIA增宽77%(P<0.01)。
  • 深部纵裂内CAIA对引流静脉手术自由度较IAIA增加54%(P=0.01)。
  • 深部纵裂内CAIA对同侧大脑前动脉手术自由度较IAIA增加98%(P=0.02)。
  • 深部纵裂内CAIA对对侧大脑前动脉手术自由度较IAIA增加117%(P<0.01)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The contralateral anterior interhemispheric approach (CAIA) is considered to provide surgical advantages to access deep midline lesions: wider working angle, gravity enhanced dissection and retraction, more efficient lighting, and ergonomics. Our team has previously published on the merits of using a contralateral trajectory for medial frontoparietal arteriovenous malformations (AVMs) compared with the conventional anterior interhemispheric approach (IAIA). In this article, we compare the IAIA and CAIA for the resection of medial frontoparietal AVMs using quantitative surgical and anatomical analysis. METHODS: Two models were designed mimicking the most common features of midline AVMs. The CAIA and IAIA were performed bilaterally in 10 specimens. Variables to compare technical feasibility (surgical window [SW] and surgical freedom [SF], target exposure, and angle of attack) were independently assessed using stereotactic navigation. The average SW, SF, and angle of attack were compared with the Student t test. Significance threshold was set at 0.05. RESULTS: The CITA and IAIA were similar in terms of SW, target exposure, and SF in the superior aspect of the AVM. In the depth of the interhemispheric fissure, the CAIA was significantly superior to IAIA in both AVM models: 77% wider AA for the inferior aspect of the AVM (P < 0.01) and greater SF for the draining vein (54%, P = 0.01), ipsilateral (98%, P = 0.02), and contralateral ACA (117%, P < 0.01). CONCLUSIONS: This study suggests technical superiority of the CAIA for the resection of deep midline AVMs. No objective difference was noted in the superficial areas of our models, denoting that IAIA is a safer choice for superficial AVMs. Our results set the foundation for further clinical analysis comparing both approaches.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. García-García S, González-Sánchez JJ, Gandhi S, et al. Contralateral Transfalcine Versus Ipsilateral Anterior Interhemispheric Approach for Midline Arteriovenous Malformations: Surgical and Anatomical Assessment. World Neurosurg. 2018. PMID: 30144605. doi:10.1016/j.wneu.2018.08.074

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。