利用术前CT扫描识别徒手置入脑室外引流管位置欠佳风险患者
该回顾性研究纳入2014年1月1日至2015年12月31日加拿大埃德蒙顿一级创伤中心189例经前额钻孔徒手置入脑室外引流管的成年患者,评估基线临床病史和术前CT特征对引流管位置欠佳(Kakarla分级)的预测作用。51例(27%)位置欠佳,15例(8%)置入 eloquent cortex 或非目标脑脊液间隙;入院诊断、轴位头高宽比和主要病变侧别与位置欠佳显著相关,头高宽比降低也与置入仅 eloquent cortex 和/或非目标脑脊液间隙相关。
要点
- 徒手置入脑室外引流管中27%(51/189)位置欠佳,8%(15/189)置入 eloquent cortex 或非目标脑脊液间隙。
- 入院诊断、轴位头高宽比和主要病变侧别与位置欠佳显著相关(P=0.02、0.012、0.02)。
- 头高宽比降低与置入仅 eloquent cortex 和/或非目标脑脊液间隙相关(P=0.003)。
核心结论
- 徒手置入脑室外引流管与显著的位置欠佳(置入脑实质和非目标脑脊液间隙)相关,基线临床和影像特征可预测位置欠佳的可能性,患者头高宽比是位置欠佳的新型潜在影像预测指标。
研究设计与样本
- 回顾性病历审查,纳入2014年1月1日至2015年12月31日加拿大埃德蒙顿一级创伤中心连续189例经前额钻孔徒手置入脑室外引流管的成年患者。
主要发现
- 51例(27%)脑室外引流管位置欠佳,15例(8%)置入 eloquent cortex 或非目标脑脊液间隙。
- 入院诊断、轴位头高宽比和主要病变侧别与位置欠佳显著相关(P=0.02、0.012、0.02)。
- 头高宽比降低与置入仅 eloquent cortex 和/或非目标脑脊液间隙相关(P=0.003)。
临床怎么用
- 作者认为,基线临床和影像特征可预测徒手置入脑室外引流管位置欠佳的可能性,头高宽比是新型潜在影像预测指标。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Freehand insertion of external ventricular drains (EVDs) using anatomical landmarks is considered the primary method for placement, although alternative techniques have shown improved accuracy in positioning. The purpose of this study was to retrospectively evaluate which features of the baseline clinical history and preprocedural CT scan predict EVD positioning into suboptimal and unsatisfactory locations when using the freehand insertion technique. METHODS: A retrospective chart review was performed evaluating 189 consecutive adult patients who received an EVD via freehand technique through an anterior burr hole between January 1, 2014, and December 31, 2015, at a Level 1 trauma facility in Edmonton, Alberta, Canada. The primary outcome measures included features associated with suboptimal positioning (Kakarla grade 1 vs Kakarla grades 2 and 3). The secondary outcome measures were features associated with unsatisfactory positioning (Kakarla grades 1 and 2 vs Kakarla grade 3). RESULTS: Fifty-one EVDs (27%) were suboptimally positioned. Fifteen (8%) EVDs were placed into eloquent cortex or nontarget CSF spaces. Admitting diagnosis, head height-to-width ratio in axial plane, and side of predominant pathology were found to be significantly associated with suboptimal placement (p = 0.02, 0.012, and 0.02, respectively). A decreased height-to-width ratio was also associated with placement into only eloquent cortex and/or nontarget CSF spaces (p = 0.003). CONCLUSIONS: Freehand insertion of an EVD is associated with significant suboptimal positioning into parenchyma and nontarget CSF spaces. The likelihood of inaccurate EVD placement can be predicted with baseline clinical and radiographic features. The patient's height-to-width ratio represents a novel potential radiographic predictor for malpositioning.
引用
- Wilson MP, O'Kelly C, Jack AS, et al. Utilizing preprocedural CT scans to identify patients at risk for suboptimal external ventricular drain placement with the freehand insertion technique. J Neurosurg. 2018. PMID: 29999445. doi:10.3171/2018.1.JNS172839
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。