T9植入桨状电极脊髓刺激后胸段脊髓受压及脑脊液空间减少:三维脊髓造影计算机断层扫描研究
本研究对15例因神经病理性背部和腿部疼痛在T9植入桨状电极脊髓刺激的患者,于术前和术后行三维脊髓造影计算机断层扫描,测量电极各触点下硬膜囊和脊髓截面积、前后脑脊液空间宽度及电极接触角,并评估12个月疼痛缓解。结果显示电极触点下硬膜囊和脊髓截面积显著减小,后侧脑脊液空间宽度减小38.65±20.97%,前侧减小更甚达59.09±18.39%,12个月平均疼痛缓解45.49±13.73%,且与脊髓面积减小百分比显著相关。
要点
- T9桨状电极植入后7天内,触点下硬膜囊和脊髓截面积显著减小。
- 前侧脑脊液空间宽度减小59.09±18.39%,大于后侧的38.65±20.97%。
- 12个月平均疼痛缓解45.49±13.73%,与脊髓面积减小百分比显著相关。
核心结论
- T9桨状电极植入后7天内,脊髓截面积、前侧脑脊液空间、硬膜囊和后侧脑脊液空间均显著减小,导致脊髓在电极下变形。
- 电极与背柱的紧密贴近及桨状电极的占位效应可能决定临床结局,并引起安全性担忧。
研究设计与样本
- 对15例因神经病理性背部和腿部疼痛在T9植入桨状电极脊髓刺激的患者,行术前和术后三维脊髓造影计算机断层扫描。
- 在每个电极行之间选取4个轴位层面,测量硬膜囊和脊髓截面积、前后脑脊液空间宽度及电极在T9椎管内的接触角,并结合12个月疼痛缓解评估。
主要发现
- 桨状电极各触点下硬膜囊截面积减小23.89±11.48%,脊髓截面积减小9.45±4.80%(P<0.05)。
- 后侧脑脊液空间宽度减小38.65±20.97%,前侧脑脊液空间宽度减小59.09±18.39%(P<0.05)。
- 12个月随访时平均疼痛缓解45.49±13.73%,与脊髓面积减小百分比显著相关。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To investigate the extent of spinal cord compression and cerebrospinal fluid (CSF) space after T9 paddle lead spinal cord stimulation (SCS) using three-dimensional myelographic computed tomography scans. METHODS: Preoperative and postoperative three-dimensional myelographic computed tomography scans were performed in 15 patients with paddle lead SCS at T9 for neuropathic back and leg pain. Four axial levels between each row of the electrodes were selected and the cross-sectional areas of thecal sac and spinal cord, the width of anterior and posterior CSF space, and contact angle of the lead within T9 spinal canal were measured with 12-month pain relief assessment. RESULTS: The cross-sectional areas of thecal sac and spinal cord under each contact of paddle leads decreased significantly (23.89 ± 11.48% and 9.45 ± 4.80%; P < 0.05, respectively). The width of posterior CSF space decreased by 38.65 ± 20.97% and that of anterior CSF space showed a greater reduction by 59.09 ± 18.39% (P < 0.05). We achieved a mean pain relief of 45.49 ± 13.73% at 12-month follow-up and found a significant correlation with percentage reduction in the area of the spinal cord. CONCLUSIONS: Significant reduction in the cross-sectional area of spinal cord and anterior CSF space as well as thecal sac and posterior CSF space resulted in deformation of the spinal cord under paddle leads at T9 within 7 postoperative days. Close approximation to the dorsal column and the mass effect of paddle leads may determine the clinical outcome of paddle lead SCS and also raise safety concerns.
引用
- Son BC, Ko HC, Choi JG, et al. Compression of Thoracic Spinal Cord with Decreased Cerebrospinal Fluid Space After Implantation of Paddle Lead Spinal Cord Stimulation at T9: A Three-Dimensional Myelographic Computed Tomography Study. World Neurosurg. 2018. PMID: 29969740. doi:10.1016/j.wneu.2018.06.186
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。