使用剪切波超声在犬体内评估脊髓弹性
研究对10只灰狗行3节段颈中段椎板切除术后,用剪切波弹性成像(SWE)在体评估脊髓弹性(SCE)。基线平均SCE为18.5±7 kPa,13 mm球囊压迫后SCE升至233±73 kPa,显著高于基线和8 mm压迫;结论认为SWE在体评估SCE可行,受压脊髓较自由脊髓更硬且随压迫增加呈线性升高。
要点
- 10只灰狗在体SWE测得基线脊髓弹性平均18.5±7 kPa。
- 13 mm球囊压迫后脊髓弹性233±73 kPa,高于基线和8 mm压迫。
- 作者认为SWE在体评估脊髓弹性可行,受压脊髓更硬。
核心结论
- 作者认为使用SWE在体评估脊髓弹性可行,且与既往脊髓物理切片报道相当。
- 受压脊髓比自由脊髓更硬,脊髓弹性随机械压迫增加呈线性升高。
研究设计与样本
- 动物实验:10只灰狗(平均年龄14个月,平均体重14.3 kg)麻醉并气管插管,行血流动力学和神经功能监测。
- 行3节段颈中段椎板切除术,基线评估脊髓弹性,随后在脊髓腹侧依次施加8 mm和13 mm球囊压迫。
主要发现
- 基线平均脊髓弹性为18.5±7 kPa。
- 中央管、软膜和硬膜弹性分别为21.7±9.6 kPa、26.1±14.8 kPa和63.2±11.5 kPa。
- 脊髓弹性低于硬膜(p < 0.0001),低于软膜的趋势接近显著(p = 0.08)。
- 13 mm球囊压迫后脊髓弹性为233±73 kPa,高于基线18.5±7 kPa(p < 0.0001)。
- 13 mm球囊压迫后脊髓弹性233±73 kPa高于8 mm球囊压迫的185±68 kPa(p < 0.048)。
临床怎么用
- 作者认为了解包括脊髓弹性在内的脊髓生物力学特性对疾病管理和预后预测具有潜在意义。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Evaluation of living tissue elasticity has wide applications in disease characterization and prognosis prediction. Few previous ex vivo attempts have been made to characterize spinal cord elasticity (SCE). Recently, tissue elasticity assessment has been clinically feasible using ultrasound shear wave elastography (SWE). The current study aims to characterize SCE in healthy dogs, in vivo, utilizing SWE, and to address SCE changes during compression. METHODS: Ten Greyhound dogs (mean age 14 months; mean weight 14.3 kg) were anesthetized and tracheally intubated, with hemodynamic and neurological monitoring. A 3-level, midcervical laminectomy was performed. SCE was assessed at baseline. Next, 8- and 13-mm balloon compressions were sequentially applied ventral to the spinal cord. RESULTS: The mean SCE was 18.5 ± 7 kPa. Elasticity of the central canal, pia mater, and dura mater were 21.7 ± 9.6 kPa, 26.1 ± 14.8 kPa, and 63.2 ± 11.5 kPa, respectively. As expected, the spinal cord demonstrated less elasticity than the dura mater (p < 0.0001) and pia mater (trend toward significance p = 0.08). Notably, the 13-mm balloon compression resulted in a stiffer spinal cord than at baseline (233 ± 73 kPa versus 18.5 ± 7 kPa, p < 0.0001) and 8-mm balloon compression (233 ± 73 kPa versus 185 ± 68 kPa, p < 0.048). CONCLUSIONS: In vivo SCE evaluation using SWE is feasible and comparable to earlier reports, as demonstrated by physical sectioning of the spinal cord. The compressed spinal cord is stiffer than a free spinal cord, with a linear increase in SCE with increasing mechanical compression. Knowledge of the biomechanical properties of the spinal cord including SCE has potential implications for disease management and prognosis.
引用
- Al-Habib A, Albakr A, Al Towim A, et al. In vivo assessment of spinal cord elasticity using shear wave ultrasound in dogs. J Neurosurg Spine. 2018. PMID: 30028252. doi:10.3171/2018.2.SPINE171195