文献速递神经肿瘤

欧洲专科中心低级别胶质瘤影像实践及最小核心影像方案建议

Imaging practice in low-grade gliomas among European specialized centers and proposal for a minimum core of imaging.
PubMed 文献 · J Neurooncol · 2018-07-10

该研究通过在线问卷调查欧洲低级别胶质瘤网络、欧洲神经外科学会、德国神经外科学会和奥地利神经外科学会成员,共分析128份完整问卷,多数中心为学术中心(96个,75%),半数中心(64个,50%)遵循专门的低级别胶质瘤治疗方案。结论提出由T1(平扫及增强)、T2、TIRM/FLAIR、PWI和DWI组成的最小核心影像方案,所有形态学图像层厚应≤3 mm;高级MRI方案和PET无共同标准。

要点

  • 128份完整问卷中,96个中心(75%)为学术中心,64个中心(50%)遵循专门的低级别胶质瘤治疗方案。
  • 多数中心纳入T1平扫及增强(100%)、T2(100%)和TIRM或FLAIR(98%);80%的中心行DWI,61%的中心常规行PWI。
  • 结论提出最小核心影像包括T1(平扫及增强)、T2、TIRM/FLAIR、PWI和DWI,形态学图像层厚应≤3 mm;高级MRI方案和PET无共同标准。

核心结论

  • 可确定由T1(平扫及增强)、T2、TIRM/FLAIR、PWI和DWI组成的最小核心影像方案。
  • 所有形态学图像应获取层厚≤3 mm。
  • 关于高级MRI方案和PET未能获得共同标准。

研究设计与样本

  • 在线问卷调查,共46个项目,发送给欧洲低级别胶质瘤网络、欧洲神经外科学会、德国神经外科学会和奥地利神经外科学会的成员。
  • 共收到并分析128份完整填写的问卷。

主要发现

  • 大多数中心(n=96,75%)为学术中心,一半中心(n=64,50%)遵循专门的低级别胶质瘤治疗方案。
  • 纳入MRI序列和PET使用存在国家间差异,但多数中心纳入T1(平扫及增强,100%)、T2(100%)和TIRM或FLAIR(98%)。
  • 80%的中心行DWI,61%的中心常规行PWI。

关键数值与推荐

  • 最小核心影像包括T1(平扫及增强)、T2、TIRM/FLAIR、PWI和DWI。
  • 所有形态学图像层厚应≤3 mm。

临床怎么用

  • 在临床常规中使用所提出的「最小核心影像」将促进未来的合作研究。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Imaging studies in diffuse low-grade gliomas (DLGG) vary across centers. In order to establish a minimal core of imaging necessary for further investigations and clinical trials in the field of DLGG, we aimed to establish the status quo within specialized European centers. METHODS: An online survey composed of 46 items was sent out to members of the European Low-Grade Glioma Network, the European Association of Neurosurgical Societies, the German Society of Neurosurgery and the Austrian Society of Neurosurgery. RESULTS: A total of 128 fully completed surveys were received and analyzed. Most centers (n = 96, 75%) were academic and half of the centers (n = 64, 50%) adhered to a dedicated treatment program for DLGG. There were national differences regarding the sequences enclosed in MRI imaging and use of PET, however most included T1 (without and with contrast, 100%), T2 (100%) and TIRM or FLAIR (20, 98%). DWI is performed by 80% of centers and 61% of centers regularly performed PWI. CONCLUSION: A minimal core of imaging composed of T1 (w/wo contrast), T2, TIRM/FLAIR, PWI and DWI could be identified. All morphologic images should be obtained in a slice thickness of ≤ 3 mm. No common standard could be obtained regarding advanced MRI protocols and PET. IMPORTANCE OF THE STUDY: We believe that our study makes a significant contribution to the literature because we were able to determine similarities in numerous aspects of LGG imaging. Using the proposed "minimal core of imaging" in clinical routine will facilitate future cooperative studies.

来源:J Neurooncol,查看原文。版权归原作者所有。

引用

  1. Freyschlag CF, Krieg SM, Kerschbaumer J, et al. Imaging practice in low-grade gliomas among European specialized centers and proposal for a minimum core of imaging. J Neurooncol. 2018. PMID: 29992433. doi:10.1007/s11060-018-2916-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。