文献速递神经肿瘤

通过扩散加权成像的概率量化在低级别胶质瘤切除后早期勾画残留肿瘤

Early postoperative delineation of residual tumor after low-grade glioma resection by probabilistic quantification of diffusion-weighted imaging.
PubMed 文献 · J Neurosurg · 2018-07-27

本研究回顾性纳入43例初次手术的低级别胶质瘤(LGG)患者,评估将表观扩散系数(ADC)图整合到术后早期MRI(<72小时)能否准确估计残留肿瘤。结果显示,概率聚类后早期MRI肿瘤体积与3-6个月随访MRI无显著差异(7.6±10.2 ml vs 8.4±10.2 ml,p=0.16),一致性良好;作者指出该方法的预后价值和临床影响需在未来更大样本中评估。

要点

  • 早期术后MRI的FLAIR高信号显著大于随访MRI(19.4±16.5 ml vs 8.4±10.2 ml,p<0.0001)。
  • ADC概率聚类将早期残留信号分为肿瘤、缺血和正常白质,显著降低量化误差。
  • 聚类后早期肿瘤体积与随访参考无显著差异(7.6±10.2 ml vs 8.4±10.2 ml,p=0.16)。

核心结论

  • ADC图的概率分割有助于在LGG切除后72小时内准确评估残留肿瘤。
  • 多参数图像分析检出归因于手术创伤的FLAIR信号改变,导致早期MRI较随访MRI高估残留LGG。
  • 该方法的预后价值和临床影响需在未来更大样本中评估。

研究设计与样本

  • 回顾性连续队列研究,纳入43例初次手术的LGG患者,均有完整早期MRI(切除后<72小时)和包含ADC图的随访MRI。

主要发现

  • 早期MRI提示残留肿瘤的平均FLAIR高信号显著大于随访MRI(19.4±16.5 ml vs 8.4±10.2 ml,p<0.0001)。
  • 早期ADC直方图概率聚类识别出平均残留肿瘤(7.6±10.2 ml)、缺血(8.1±5.9 ml)和正常白质(3.7±4.9 ml)亚区。
  • 早期MRI与随访MRI之间的平均肿瘤量化误差显著降低(11.0±10.6 ml vs -0.8±3.7 ml,p<0.0001)。
  • 聚类后早期肿瘤体积与随访MRI参考无显著差异(7.6±10.2 ml vs 8.4±10.2 ml,p=0.16)。
  • Pearson相关系数r=0.96(p<0.0001),一致性相关系数0.89(95%CI 0.83),Bland-Altman分析提示聚类后两种测量高度一致。

局限性

  • 该方法的预后价值和临床影响需在未来更大样本中评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: In WHO grade II low-grade gliomas (LGGs), early postoperative MRI (epMRI) may overestimate residual tumor on FLAIR sequences. Consequently, MRI at 3-6 months follow-up (fuMRI) is used for delineation of residual tumor. This study sought to evaluate if integration of apparent diffusion coefficient (ADC) maps permits an accurate estimation of residual tumor early on epMRI. METHODS: From a consecutive cohort, 43 cases with an initial surgery for an LGG, and complete epMRI (< 72 hours after resection) and fuMRI including ADC maps, were retrospectively identified. Residual FLAIR hyperintense tumor was manually segmented on epMRI and corresponding ADC maps were coregistered. Using an expectation maximization algorithm, residual tumor segments were probabilistically clustered into areas of residual tumor, ischemia, or normal white matter (NWM) by fitting a mixture model of superimposed Gaussian curves to the ADC histogram. Tumor volumes from epMRI, clustering, and fuMRI were statistically compared and agreement analysis was performed. RESULTS: Mean FLAIR hyperintensity suggesting residual tumor was significantly larger on epMRI compared to fuMRI (19.4 ± 16.5 ml vs 8.4 ± 10.2 ml, p < 0.0001). Probabilistic clustering of corresponding ADC histograms on epMRI identified subsegments that were interpreted as mean residual tumor (7.6 ± 10.2 ml), ischemia (8.1 ± 5.9 ml), and NWM (3.7 ± 4.9 ml). Therefore, mean tumor quantification error between epMRI and fuMRI was significantly reduced (11.0 ± 10.6 ml vs -0.8 ± 3.7 ml, p < 0.0001). Mean clustered tumor volumes on epMRI were no longer significantly different from the fuMRI reference (7.6 ± 10.2 ml vs 8.4 ± 10.2 ml, p = 0.16). Correlation (Pearson r = 0.96, p < 0.0001), concordance correlation coefficient (0.89, 95% confidence interval 0.83), and Bland-Altman analysis suggested strong agreement between both measures after clustering. CONCLUSIONS: Probabilistic segmentation of ADC maps facilitates accurate assessment of residual tumor within 72 hours after LGG resection. Multiparametric image analysis detected FLAIR signal alterations attributable to surgical trauma, which led to overestimation of residual LGG on epMRI compared to fuMRI. The prognostic value and clinical impact of this method has to be evaluated in larger case series in the future.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Scherer M, Jungk C, Götz M, et al. Early postoperative delineation of residual tumor after low-grade glioma resection by probabilistic quantification of diffusion-weighted imaging. J Neurosurg. 2018. PMID: 30052158. doi:10.3171/2018.2.JNS172951

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。