文献速递神经肿瘤

弥漫性胶质瘤在初始神经影像学上被误诊的特征:一项病例对照研究

Features of diffuse gliomas that are misdiagnosed on initial neuroimaging: a case control study.
PubMed 文献 · J Neurooncol · 2018-06-29

这项回顾性病例对照研究纳入18例初始神经影像误诊的弥漫性胶质瘤(病例)和108例初始神经影像准确诊断的弥漫性胶质瘤(对照),比较临床、病理和影像指标。误诊病例更常按卒中流程分诊(OR 14.429)、更少强化(OR 0.283)、直径更小(均值4.4 vs 6.0 cm)、中线移位更少(中位0.0 vs 2.0 mm)、更少坏死(OR 0.156)且初始MRI更少使用静脉对比剂(OR 0.100)。作者认为了解这些关联可能有助于避免误判并准确诊断此类病例。

要点

  • 误诊病例更常被按卒中流程分诊(OR 14.429,95%CI 4.345-47.915,p<0.0001)。
  • 误诊病例更少强化(OR 0.283)、更少坏死(OR 0.156)且初始MRI更少用静脉对比剂(OR 0.100)。
  • 误诊病例直径更小(均值4.4 vs 6.0 cm)且中线移位更少(中位0.0 vs 2.0 mm)。

核心结论

  • 若干临床和影像学指标与初始神经影像上被漏诊或误诊的弥漫性胶质瘤相关,了解这些关联可能有助于在临床实践中避免误判并准确诊断此类病例。

研究设计与样本

  • 回顾性病例对照分析,纳入18例初始神经影像误诊的弥漫性胶质瘤(病例)和108例初始神经影像准确诊断的弥漫性胶质瘤(对照),比较临床、病理和影像指标。

主要发现

  • 误诊病例较对照更常按卒中流程分诊(OR 14.429,95%CI 4.345-47.915,p<0.0001)。
  • 误诊病例较对照更少强化(OR 0.283,95%CI 0.098-0.812,p=0.02)。
  • 误诊病例较对照直径更小(均值4.4 vs 6.0 cm,p=0.0008)。
  • 误诊病例较对照中线移位更少(中位0.0 vs 2.0 mm,p=0.003)。
  • 误诊病例较对照更少坏死(OR 0.156,95%CI 0.034-0.713,p=0.008)且初始MRI更少使用静脉对比剂(OR 0.100,95%CI 0.020-0.494,p=0.008)。

临床怎么用

  • 作者认为了解这些关联可能有助于避免误判并准确诊断此类病例。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The neuroimaging diagnosis of diffuse gliomas can be challenging owing to their variable clinical and radiologic presentation. The purpose of this study was to identify factors that are associated with imaging errors in the diagnosis of diffuse gliomas. METHODS: A retrospective case-control analysis was undertaken. 18 misdiagnosed diffuse gliomas on initial neuroimaging (cases) and 108 accurately diagnosed diffuse gliomas on initial neuroimaging (controls) were collected. Clinical, pathological, and imaging metrics were tabulated for each patient. The tabulated metrics were compared between cases and controls to determine factors associated with misdiagnosis. RESULTS: Cases of misdiagnosed diffuse glioma (vs controls) were more likely to undergo initial triage as a stroke workup [OR 14.429 (95% CI 4.345, 47.915), p < 0.0001], were less likely to enhance [OR 0.283 (95% CI 0.098, 0.812), p = 0.02], were smaller (mean diameter 4.4 vs 6.0 cm, p = 0.0008), produced less midline shift (median midline shift 0.0 vs 2.0 mm, p = 0.003), were less likely to demonstrate necrosis [OR 0.156 (95% CI 0.034-0.713), p = 0.008], and were less likely to have IV contrast administered on the initial MRI [OR 0.100 (95% CI 0.020, 0.494), p = 0.008]. CONCLUSION: Several clinical and radiologic metrics are associated with diffuse gliomas that are missed or misdiagnosed on the initial neuroimaging study. Knowledge of these associations may aid in avoiding misinterpretation and accurately diagnosing such cases in clinical practice.

来源:J Neurooncol,查看原文。版权归原作者所有。

引用

  1. Maldonado MD, Batchala P, Ornan D, et al. Features of diffuse gliomas that are misdiagnosed on initial neuroimaging: a case control study. J Neurooncol. 2018. PMID: 29959694. doi:10.1007/s11060-018-2939-9