激光辅助切除弹簧圈团在既往血管内栓塞后复发颅内动脉瘤夹闭术中的应用:我们的初步经验
两例既往血管内栓塞后复发颅内动脉瘤患者,因弹簧圈团重量影响载瘤血管管腔而无法安全夹闭,采用二氧化碳激光辅助切除弹簧圈团后成功夹闭,术中脑血管造影示动脉瘤完全闭塞,无并发症,1年随访无症状且无复发证据。
要点
- 二氧化碳激光辅助切除弹簧圈团在夹闭复发颅内动脉瘤时安全有效。
- 两例患者术中造影均示动脉瘤完全闭塞,无并发症。
- 1年随访两例患者均无症状,无动脉瘤复发证据。
核心结论
- 治疗既往血管内技术治疗的复发和/或残留颅内动脉瘤时需切除弹簧圈团,二氧化碳激光辅助取出这些弹簧圈安全有效。
研究设计与样本
- 两例病例报告,评估二氧化碳激光在动脉瘤手术中安全有效去除弹簧圈的应用。
主要发现
- 第一例为56岁男性,既往栓塞的破裂前交通动脉瘤,3年随访造影示复发,因技术原因无法再次栓塞,因弹簧圈团重量影响载瘤血管管腔无法安全放置动脉瘤夹,永久夹闭前行激光辅助弹簧圈团切除,术中脑血管造影示动脉瘤完全闭塞。
- 第二例为69岁女性,既往栓塞的未破裂大脑中动脉瘤,2年随访造影示复发,因技术原因无法再次栓塞,安全夹闭动脉瘤前行激光辅助弹簧圈团切除,术中造影示动脉瘤完全闭塞。
- 使用二氧化碳激光未发生并发症,1年随访两例患者均无症状,无动脉瘤复发证据。
临床怎么用
- 作者认为,对于既往血管内技术治疗的复发和/或残留颅内动脉瘤,治疗时需切除弹簧圈团,二氧化碳激光辅助取出弹簧圈安全有效。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Excision of coil mass during clipping of recurrent or residual aneurysms after prior endovascular coiling is challenging. We evaluated the use of the carbon dioxide laser for safe and effective removal of coils during aneurysm surgery. Two cases are presented. CASE DESCRIPTION: The first patient was a 56-year-old man with a previously coiled ruptured anterior communicating artery aneurysm. Angiography at 3-year follow-up showed recurrent aneurysm, which could not be coiled again owing to technical reasons. An aneurysm clip could not be safely applied owing to the weight of the coil mass compromising the parent vessel lumen. Laser-assisted coil mass resection was performed before permanent clip application. Intraoperative cerebral angiography showed complete obliteration of the aneurysm. The second patient was a 69-year-old woman with a previously coiled unruptured middle cerebral artery aneurysm. Angiography at 2-year follow-up showed recurrence of the aneurysm, which could not be coiled again owing to technical reasons. Laser-assisted coil mass resection was performed before the aneurysm was safely clipped. Intraoperative angiography showed complete obliteration of the aneurysm. No complications occurred using the carbon dioxide laser. At 1-year follow-up, both patients were asymptomatic with no evidence of aneurysmal recurrence. CONCLUSIONS: Excision of coil mass is required while treating recurrent and/or residual intracranial aneurysms that were previously treated by endovascular technique. The use of carbon dioxide laser assistance while retrieving these coils is safe and effective.
引用
- Chamiraju P, Moon SJ, Maddali P, et al. Laser-Assisted Excision of Coil Mass While Clipping Recurrent Intracranial Aneurysms After Prior Endovascular Coiling: Our Initial Experience. World Neurosurg. 2018. PMID: 29969741. doi:10.1016/j.wneu.2018.06.177
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。