使用支架取栓器血管内取出大脑中动脉远端移位的弹簧圈
本文报告一例球囊辅助弹簧圈栓塞交通段颈内动脉动脉瘤术中弹簧圈向远端大脑中动脉移位,使用支架取栓器成功取出。作者回顾性分析病历资料,认为支架取栓器通过支柱咬合机制可在不完全捕获目标的情况下成功取出弹簧圈,尤其适用于迂曲细小远端血管。
要点
- 颅内动脉瘤栓塞术中弹簧圈移位是潜在危及生命的并发症。
- 支架取栓器取出移位弹簧圈时不必完全捕获目标。
- 支架取栓器可置于相对欠佳位置,适用于直径小于2 mm的迂曲远端血管。
核心结论
- 在某些情况下,支架取栓器不要求完全捕获目标即可成功取出移位弹簧圈。
- 由于支柱咬合的机械优势,支架取栓器可置于相对欠佳的位置,尤其适用于迂曲细小的远端血管(直径小于2 mm)。
研究设计与样本
- 病例报告,回顾性分析患者病历资料,包括临床与影像学信息。
- 研究获得机构审查委员会批准。
主要发现
- 患者接受球囊辅助弹簧圈栓塞颈内动脉动脉瘤。
- 弹簧圈向远端移位至大脑中动脉,使用支架取栓器成功取出。
- 据作者所知,这是使用支架取栓器成功取出的最远距离移位的弹簧圈。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Displacement of endovascular coils during endovascular embolization of an intracranial aneurysm is a potentially life-threatening complication. Several methods for coil retrieval have been described, including the use of microsnares and microforceps retrieval devices. With the recent surge of stentriever implementation in the treatment of ischemic stroke, some operators are now using such devices in the retrieval of migrated coils. We present a case of a balloon-assisted coil embolization of a communicating segment internal carotid artery aneurysm, complicated by coil migration far distally into the middle cerebral artery, which was retrieved successfully with a stentriever. To the best of our knowledge, this is the furthest migration of a coil to be successfully retrieved with a stentriever. We review conservative and invasive management of displaced coils and the technical advantages of stentrievers over retrieval devices. METHODS: The patient's medical records were retrospectively reviewed, including clinical and radiographic information. This study received institutional review board approval. RESULTS: The patient was treated with balloon-assisted coil embolization of the internal carotid artery aneurysm. The migrated coil was retrieved successfully using a novel application of a stentriever. CONCLUSIONS: In certain situations, a stentriever does not mandate complete ensnaring of the target to be retrieved and thus need not always be deployed distal to a migrated coil mass to be successful. Due to the mechanical advantage of strut-engagement, stentrievers can afford to be positioned in relatively suboptimal positions, and this is especially useful in cases involving tortuous and small distal vessels (<2 mm diameter).
引用
- Amuluru K, Al-Mufti F, Romero CE, et al. Endovascular Retrieval of Migrated Coil within the Distal Middle Cerebral Artery Using Stentriever Device. World Neurosurg. 2018. PMID: 29966785. doi:10.1016/j.wneu.2018.06.175
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。