分支嵌入的未破裂大脑中动脉动脉瘤血管内弹簧圈栓塞的可行性与中期结局

Feasibility and Midterm Outcomes of Endovascular Coil Embolization of an Unruptured Middle Cerebral Artery Aneurysm with an Incorporated Branch.
PubMed 文献 · World Neurosurg · 2018-08-04

该研究回顾性分析了2012至2017年治疗的10例分支嵌入的未破裂大脑中动脉动脉瘤患者,采用双微导管技术9例、三微导管技术1例进行弹簧圈栓塞。术后造影显示4例完全闭塞(40%)、5例残留瘤颈(50%)、1例残留瘤囊(10%),随访(26.0±4.5个月)期间无复发和出血。作者认为分支嵌入的大脑中动脉动脉瘤可行动脉瘤栓塞治疗,操作并发症少且中期疗效持久。

要点

  • 10例分支嵌入的未破裂大脑中动脉动脉瘤采用弹簧圈栓塞,9例用双微导管技术、1例用三微导管技术。
  • 术后造影完全闭塞4例(40%)、残留瘤颈5例(50%)、残留瘤囊1例(10%),无操作相关并发症。
  • 随访(26.0±4.5个月;范围3-49个月)无复发和出血,1例术后1个月发生小脑梗死但无永久性神经功能缺损。

核心结论

  • 分支嵌入的大脑中动脉动脉瘤可行动脉瘤栓塞治疗,操作并发症少,在适当技术和器械下中期疗效持久。

研究设计与样本

  • 回顾性分析2012至2017年治疗的129例未破裂动脉瘤,其中10例为分支嵌入的大脑中动脉动脉瘤。
  • 动脉瘤平均瘤颈、高度和宽度分别为3.74±1.07、4.26±1.06和3.97±1.03。
  • 平均纵横比、瘤颈/瘤囊宽度和瘤囊宽度/瘤颈分别为1.19±0.37、1.09±0.21和0.95±0.18。

主要发现

  • 9例分支嵌入的大脑中动脉动脉瘤采用双微导管技术治疗,1例采用三微导管技术治疗。
  • 无操作相关并发症。
  • 术后弹簧圈造影显示4例动脉瘤完全闭塞(40%)、5例残留瘤颈(50%)、1例残留瘤囊(10%)。
  • 随访期间(26.0±4.5个月;范围3-49个月)无复发和出血事件。
  • 1例患者术后1个月发生小脑梗死,但未导致永久性神经功能缺损。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Endovascular coiling has emerged as an option for the management of unruptured intracranial aneurysms, which was traditionally treated via surgical clipping. Unlike aneurysms elsewhere, aneurysms of the middle cerebral artery (MCA) have several features that are favorable for surgery. However, endovascular treatment can be difficult for MCA aneurysms, especially if they have incorporated branches. We report the results of coil embolization of incorporated MCA aneurysms. METHODS: From 2012 to 2017, 129 unruptured aneurysms including 10 incorporated MCA aneurysms were treated. The mean neck, height, and width of the aneurysms were 3.74 ± 1.07, 4.26 ± 1.06, and 3.97 ± 1.03, respectively. The mean aspect ratio, neck/sac width, and sac width/neck were 1.19 ± 0.37, 1.09 ± 0.21, and 0.95 ± 0.18, respectively. RESULTS: Nine cases of incorporated MCA aneurysms were treated using the double microcatheter technique, whereas the triple microcatheter technique was used in 1 case. There were no procedure-related complications. Postcoiling angiograms showed that 4 aneurysms achieved complete occlusion (40%), 5 had a remnant neck (50%), and 1 had a remnant sac (10%). During the follow-up period, (26.0 ± 4.5 months; range, 3-49 months), there were no incidents of recurrence and bleeding. One patient experienced a small cerebral infarction 1 month after the procedure, but it did not lead to any permanent neurologic deficits. CONCLUSIONS: Branch-incorporated MCA aneurysms can be treated with coil embolization, with few procedural complications and midterm durability with appropriate techniques and devices.

来源:World Neurosurg,查看原文。版权归原作者所有。