文献速递脑血管病外科神经重症

动脉瘤手术中监测眼外压力以避免眶腔间隙综合征

Extraocular Pressure Measurements to Avoid Orbital Compartment Syndrome in Aneurysm Surgery.
PubMed 文献 · World Neurosurg · 2018-07-07

本研究在86例经翼点入路脑动脉瘤手术患者中使用眼外压力监测仪测量眼外压力,并与117例未监测患者对照。结果显示皮肌瓣可对眶产生未被察觉的过高压力,监测组在前交通动脉瘤患者中内直肌肿胀比显著低于对照组(1.03±0.10 vs 1.17±0.15,P=0.036)。

要点

  • 皮肌瓣可对眶产生未被察觉的过高压力,可能导致动脉瘤夹闭术中眶腔间隙综合征相关失明。
  • 眼外压力在开颅时达到最大值(均值22.0 mmHg,范围18.4-51.0 mmHg),调整皮肌瓣后下降(均值7.9 mmHg,范围5.4-17.5 mmHg)。
  • 前交通动脉瘤患者皮肌瓣操作前压力与其他患者不同(均值16.5 mmHg vs 9.4 mmHg,P=0.003)。

核心结论

  • 皮肌瓣可对眶产生未被察觉的过高压力,导致动脉瘤夹闭术中眶腔间隙综合征相关失明,尤其在需低位开颅的病例中。
  • 连续眼外压迫压力监测技术是预防这一严重并发症的简单有效方法。

研究设计与样本

  • 研究测量了86例经翼点入路脑动脉瘤手术患者的眼外压力,并收集临床信息和影像学参数(包括内直肌面积和自前颅底底部的开颅高度)。
  • 另设117例未进行压力监测的手术患者作为对照组。

主要发现

  • 眼外压力在开颅时达到最大值(均值22.0 mmHg,范围18.4-51.0 mmHg),调整皮肌瓣后下降(均值7.9 mmHg,范围5.4-17.5 mmHg)。
  • 前交通动脉瘤患者与其他患者皮肌瓣操作前压力不同(均值16.5 mmHg vs 9.4 mmHg,P=0.003)。
  • 前交通动脉瘤病例中,监测组内直肌肿胀比(术后内直肌面积/术前内直肌面积)显著低于对照组(1.03±0.10 vs 1.17±0.15,P=0.036)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Orbital compartment syndrome (OCS) is a rare but devastating complication following pterional craniotomy. Although the causes of OCS are unclear, external compression of the orbit by a myocutaneous flap is commonly mentioned as a major factor. We evaluated the ocular influence of external compression using an extraocular pressure monitor. METHODS: We measured extraocular pressure in 86 patients who underwent surgery for cerebral aneurysm via a pterional approach. Clinical information and radiologic parameters, including the area of the medial rectus muscle (MRM) and the craniotomy height from the bottom of the anterior skull base, were collected. As a control group, 117 patients who underwent surgery without pressure monitoring were also evaluated. RESULTS: Extraocular pressure reached a maximum during craniotomy (mean, 22.0 mm Hg; range, 18.4-51.0 mm Hg) and decreased after myocutaneous flap adjustment (mean, 7.9 mm Hg; range, 5.4-17.5 mm Hg). Pressure before myocutaneous flap manipulation differed between patients with anterior communicating artery (Acomm) aneurysms and other patients (mean, 16.5 mm Hg vs. 9.4 mm Hg; P = 0.003). Among Acomm aneurysm cases, the monitored group showed a significantly lower MRM swelling ratio (postoperative MRM area/preoperative MRM area) compared with the control group (1.03 ± 0.10 vs. 1.17 ± 0.15; P = 0.036). CONCLUSIONS: Myocutaneous flaps can produce unnoticed overpressure on the orbit, resulting in OCS-related blindness during aneurysm clipping surgery, especially in cases involving mandatory lower craniotomy. The continuous extraocular compressive pressure monitoring technique is a simple and effective approach to prevent such a serious complication.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Kim TS, Hur JW, Park DH, et al. Extraocular Pressure Measurements to Avoid Orbital Compartment Syndrome in Aneurysm Surgery. World Neurosurg. 2018. PMID: 29990603. doi:10.1016/j.wneu.2018.06.248

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。