18F-氟脱氧葡萄糖-PET与碘马西尼-SPECT双重匹配改善致痫灶切除术预后
本研究纳入59例MRI无明确病灶的癫痫患者,均行发作间期18FDG-PET与IMZ-SPECT检查及致痫灶切除术,随访≥2年。多因素分析显示,切除灶与PET和SPECT低摄取区均一致与无发作结局显著相关(p=0.004),比值比为6.0。作者认为两种检查互补,双重一致定位优于单一检查。
要点
- MRI无病灶的癫痫患者中,18FDG-PET与IMZ-SPECT低摄取区均与切除灶一致时,无发作结局的比值比为6.0。
- 单因素分析中,PET一致(p=0.017)、SPECT一致(p=0.030)及两者均一致(p=0.006)均与无发作显著相关。
- 作者认为IMZ-SPECT与18FDG-PET在定位相关癫痫评估中互为补充。
核心结论
- 在MRI无病灶发现的患者中,发作间期18FDG-PET与IMZ-SPECT低摄取区均与切除灶一致时,对无发作结局的比值比为6.0,作者认为优于任一检查单独使用。
- 作者认为IMZ-SPECT与18FDG-PET是定位相关癫痫评估中的互补检查。
研究设计与样本
- 单中心研究,纳入59例患者(女性31例,男性28例;平均年龄29岁,中位年龄27岁,范围7-56岁),均行硬膜下电极植入后致痫灶切除术。
- 所有患者均行18FDG-PET、IMZ-SPECT及致痫灶切除术,随访持续≥2年。
- 采用单因素和多因素逻辑回归分析,评估手术结局(无发作与否)与PET、SPECT或两者低摄取区与切除灶一致性的相关性。
主要发现
- 单因素分析中,PET一致(p=0.017)、SPECT一致(p=0.030)及两者均一致(p=0.006)均与无发作结局显著相关。
- 多因素分析中,切除灶与PET和SPECT低摄取区均一致与无发作结局显著相关(p=0.004),比值比为6.0。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: When the results of electroencephalography (EEG), magnetic resonance imaging (MRI), and seizure semiology are discordant or no structural lesion is evident on MRI, single-photon emission computed tomography (SPECT) and positron emission tomography (PET) are important examinations for lateralization or localization of epileptic regions. We hypothesized that the concordance between interictal 2-[18F]fluoro-2-deoxy-D-glucose (18FDG)-PET and iomazenil (IMZ)-SPECT could suggest the epileptogenic lobe in patients with non-lesional findings on MRI. METHOD: Fifty-nine patients (31 females, 28 males; mean age, 29 years; median age, 27 years; range, 7-56 years) underwent subdural electrode implantation followed by focus resection. All patients underwent 18FDG-PET, IMZ-SPECT, and focus resection surgery. Follow-up was continued for ≥ 2 years. We evaluated surgical outcomes as seizure-free or not and analyzed correlations between outcomes and concordances of low-uptake lobes on PET, SPECT, or both PET and SPECT to the resection lobes. We used uni- and multivariate logistic regression analyses. RESULTS: In univariate analyses, all three concordances correlated significantly with seizure-free outcomes (PET, p = 0.017; SPECT, p = 0.030; both PET and SPECT, p = 0.006). In multivariate analysis, concordance between resection and low-uptake lobes in both PET and SPECT correlated significantly with seizure-free outcomes (p = 0.004). The odds ratio was 6.0. CONCLUSION: Concordance between interictal 18FDG-PET and IMZ-SPECT suggested that the epileptogenic lobe is six times better than each examination alone among patients with non-lesional findings on MRI. IMZ-SPECT and 18FDG-PET are complementary examinations in the assessment of localization-related epilepsy.
引用
- Fujimoto A, Okanishi T, Kanai S, et al. Double match of 18F-fluorodeoxyglucose-PET and iomazenil-SPECT improves outcomes of focus resection surgery. Acta Neurochir (Wien). 2018. PMID: 29858947. doi:10.1007/s00701-018-3573-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。