文献速递脊柱脊髓外科神经重症

对比增强超声可视化啮齿动物脊髓损伤后血流动力学变化

Contrast-enhanced ultrasound to visualize hemodynamic changes after rodent spinal cord injury.
PubMed 文献 · J Neurosurg Spine · 2018-06-15

本研究在大鼠胸段脊髓压迫损伤模型中开发超快对比增强超声多普勒技术,使用15 MHz线阵换能器与微泡造影剂实时分离大循环高速血流与微循环低速血流。结果显示该技术可显示脊髓前动脉与中央动脉,并在损伤后即刻描绘局部组织低灌注的空间分布图。

要点

  • 超快对比增强超声多普勒可实时显示大鼠脊髓血管结构与组织灌注。
  • 压迫损伤后脊髓血管在1.93±1.14 mm²范围内断裂。
  • 灌注低于周围保留组织40%的区域面积为2.21±0.6 mm²。

核心结论

  • 作者在本报告中引入超快对比增强超声多普勒用于实时监测脊髓血管结构与功能,并认为该类成像的开发与临床转化可能对创伤性脊髓损伤患者的诊疗产生重要影响。

研究设计与样本

  • 研究使用研究型超声平台联合15 MHz线阵换能器开发超快对比增强超声多普勒技术,采用FDA批准的微泡造影剂,在成年大鼠胸段脊髓压迫损伤模型中观察组织灌注。

主要发现

  • 高频超声可显示脊髓前动脉与中央动脉,平均直径(±SEM)分别为145.8±10.0 µm与76.2±4.5 µm。
  • 在完整脊髓中,超快对比增强超声多普勒证实灰质灌注高于白质。
  • 胸段脊髓压迫损伤后即刻,脊髓血管在1.93±1.14 mm²范围内断裂。
  • 超快对比增强超声多普勒以高空间分辨率显示局部组织低灌注的拓扑图。
  • 与周围保留组织相比灌注低于40%的关键灌注丧失区域面积为2.21±0.6 mm²。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE Traumatic spinal cord injury (tSCI) causes an almost complete loss of blood flow at the site of injury (primary injury) as well as significant hypoperfusion in the penumbra of the injury. Hypoperfusion in the penumbra progresses after injury to the spinal cord and is likely to be a major contributor to progressive cell death of spinal cord tissue that was initially viable (secondary injury). Neuroprotective treatment strategies seek to limit secondary injury. Clinical monitoring of the temporal and spatial patterns of blood flow within the contused spinal cord is currently not feasible. The purpose of the current study was to determine whether ultrafast contrast-enhanced ultrasound (CEUS) Doppler allows for detection of local hemodynamic changes within an injured rodent spinal cord in real time. METHODS A novel ultrafast CEUS Doppler technique was developed utilizing a research ultrasound platform combined with a 15-MHz linear array transducer. Ultrafast plane-wave acquisitions enabled the separation of higher-velocity blood flow in macrocirculation from low-velocity flow within the microcirculation (tissue perfusion). An FDA-approved contrast agent (microbubbles) was used for visualization of local blood flow in real time. CEUS Doppler acquisition protocols were developed to characterize tissue perfusion both during contrast inflow and during the steady-state plateau. A compression injury of the thoracic spinal cord of adult rats was induced using iris forceps. RESULTS High-frequency ultrasound enabled visualization of spinal cord vessels such as anterior spinal arteries as well as central arteries (mean diameter [± SEM] 145.8 ± 10.0 µm; 76.2 ± 4.5 µm, respectively). In the intact spinal cord, ultrafast CEUS Doppler confirmed higher perfusion of the gray matter compared to white matter. Immediately after compression injury of the thoracic rodent spinal cord, spinal cord vessels were disrupted in an area of 1.93 ± 1.14 mm2. Ultrafast CEUS Doppler revealed a topographical map of local tissue hypoperfusion with remarkable spatial resolution. Critical loss of perfusion, defined as less than 40% perfusion compared to the surrounding spared tissue, was seen within an area of 2.21 ± 0.6 mm2. CONCLUSIONS In our current report, we introduce ultrafast CEUS Doppler for monitoring of spinal vascular structure and function in real time. Development and clinical implementation of this type of imaging could have a significant impact on the care of patients with tSCI.

来源:J Neurosurg Spine,查看原文。版权归原作者所有。

引用

  1. Khaing ZZ, Cates LN, DeWees DM, et al. Contrast-enhanced ultrasound to visualize hemodynamic changes after rodent spinal cord injury. J Neurosurg Spine. 2018. PMID: 29905521. doi:10.3171/2018.1.SPINE171202

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。