Coflex棘突间植入物置入导致滑膜囊肿形成:病例报告
本文报告一例64岁女性因下腰痛在院外行L4-5 Coflex棘突间植入物置入,术后背痛及右腿痛持续并加重,MRI显示原治疗节段新发大滑膜囊肿严重压迫马尾。4个月后行植入物取出、双侧椎板切除、关节突切除、滑膜囊肿切除及椎间融合稳定术,3个月随访背痛明显改善但仍有部分腿痛。作者认为关节突关节退变可能不是Coflex置入的合适适应证。
要点
- Coflex棘突间植入物置入后可在原治疗节段新发大滑膜囊肿并严重压迫马尾。
- 该患者术后背痛及右腿痛持续并加重,MRI证实新发滑膜囊肿。
- 作者认为关节突关节退变可能不是Coflex置入的合适适应证。
核心结论
- 本病例提示关节突关节退变可能不是Coflex置入的合适适应证。
研究设计与样本
- 本文为病例报告,报告一例64岁女性在院外行L4-5 Coflex棘突间植入物置入后出现新发大滑膜囊肿。
主要发现
- 患者因偶发右腿放射的下腰痛在院外行L4-5 Coflex置入,术后背痛及右腿痛持续并加重。
- MRI显示原治疗节段新发大滑膜囊肿,严重压迫马尾。
- 4个月后行植入物取出、双侧椎板切除、关节突切除、滑膜囊肿切除、椎间融合及稳定术。
- 术后3个月随访,患者背痛明显改善,仍有部分腿痛。
临床怎么用
- 作者认为关节突关节退变可能不是Coflex置入的合适适应证。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Interspinous process devices (IPDs) have been developed as less-invasive alternatives to spinal fusion with the goal of decompressing the spinal canal and preserving segmental motion. IPD implantation is proposed to treat symptoms of lumbar spinal stenosis that improve during flexion. Recent indications of IPD include lumbar facet joint syndrome, which is seen in patients with mainly low-back pain. Long-term outcomes in this subset of patients are largely unknown. The authors present a previously unreported complication of coflex (IPD) placement: the development of a large compressive lumbar synovial cyst. A 64-year-old woman underwent IPD implantation (coflex) at L4-5 at an outside hospital for low-back pain that occasionally radiates to the right leg. Postoperatively, her back and right leg pain persisted and worsened. MRI was repeated and showed a new, large synovial cyst at the previously treated level, severely compressing the patient's cauda equina. Four months later, she underwent removal of the interspinous process implant, bilateral laminectomy, facetectomy, synovial cyst resection, interbody fusion, and stabilization. At the 3-month follow-up, she reported significant back pain improvement with some residual leg pain. This case suggests that facet arthrosis may not be an appropriate indication for placement of coflex.
引用
- Ramhmdani S, Comair M, Molina CA, et al. Coflex interspinous implant placement leading to synovial cyst development: case report. J Neurosurg Spine. 2018. PMID: 29905520. doi:10.3171/2018.1.SPINE171360
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。