文献速递神经肿瘤

鞍上扩展对压迫视交叉的无功能垂体腺瘤中国患者视功能评估的预测价值

The Predictive Value of Suprasellar Extension for Visual Function Evaluation in Chinese Patients with Nonfunctioning Pituitary Adenoma with Optic Chiasm Compression.
PubMed 文献 · World Neurosurg · 2018-05-29

该回顾性研究纳入117例伴视交叉压迫的无功能垂体腺瘤患者,分析MRI上鞍上扩展与视功能损害的定量关系。矢状位鞍上扩展预测视野缺损的截断值为14.0mm(敏感度77.9%,特异度80.0%),冠状位为15.8mm(敏感度81.8%,特异度85.0%)。鞍上扩展与视力及视野平均偏差相关,且为视野缺损程度的独立相关因素。

要点

  • 矢状位鞍上扩展预测视野缺损截断值14.0mm,敏感度77.9%,特异度80.0%。
  • 冠状位鞍上扩展预测视野缺损截断值15.8mm,敏感度81.8%,特异度85.0%。
  • 矢状位和冠状位鞍上扩展、病程及卒中与视野缺损程度相关。

核心结论

  • 伴视交叉压迫的无功能垂体腺瘤患者,其视野缺损可由MRI上的鞍上扩展预测。
  • 鞍上扩展与视野平均偏差值呈线性相关。

研究设计与样本

  • 回顾性分析2013年1月至2016年12月在本院治疗的117例伴视交叉压迫的无功能垂体腺瘤患者。
  • 分析矢状位和冠状位MRI鞍上扩展与视力、视野的定量关系,用受试者工作特征曲线计算预测视野缺损的截断值。

主要发现

  • 117例中77例(65.8%)存在视野缺损,平均视力为0.42±0.38 logMAR。
  • 矢状位鞍上扩展截断值14.0mm,敏感度77.9%,特异度80.0%;冠状位截断值15.8mm,敏感度81.8%,特异度85.0%。
  • 两个MRI切面的鞍上扩展均与视力相关(P < 0.001),与视野平均偏差相关(P < 0.001)。
  • 多因素线性回归显示矢状位鞍上扩展(P < 0.001)、冠状位鞍上扩展(P < 0.001)、病程(P = 0.027)和卒中(P = 0.036)与视野缺损程度相关。

关键数值与推荐

  • 矢状位鞍上扩展预测视野缺损的截断值为14.0mm(敏感度77.9%,特异度80.0%)。
  • 冠状位鞍上扩展预测视野缺损的截断值为15.8mm(敏感度81.8%,特异度85.0%)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To analyze the quantitative relationship between suprasellar extension (SSE) and visual function impairment in Chinese patients with nonfunctioning pituitary adenoma (NFPA) with optic chiasm compression. METHODS: We retrospectively reviewed 117 patients with NFPA and optic chiasm compression treated at our hospital between January 2013 and December 2016. The quantitative relationships between SSE detected on sagittal and coronal magnetic resonance imaging (MRI) sections and visual function, including visual acuity (VA) and visual fields (VFs), were analyzed. The cutoff value of SSE to predict a VF defect (VFD) was calculated using a receiver operating characteristic curve. The mean deviation (MD) value was used to quantitatively analyze the VFs, and multiple linear regression analysis was performed to investigate risk factors of VFD. RESULTS: Among 117 patients with NFPA, 77 (65.8%) had VFD, and the mean VA was 0.42 ± 0.38 logMAR. The cutoff value of the sagittal SSE was 14.0 mm, with 77.9% sensitivity and 80.0% specificity, and the cutoff value of the coronal SSE was 15.8 mm, with 81.8% sensitivity and 85.0% specificity. The values of SSE on 2 MRI sections were correlated with VA (P < 0.001) and the MD (P < 0.001). Multiple linear regression analysis demonstrated that SSE on sagittal views (P < 0.001), SSE on coronal views (P < 0.001), duration of the disease (P = 0.027), and apoplexy (P = 0.036) were related to the degree of VF damage. CONCLUSIONS: VFD in patients with NFPA with chiasm compression can be predicted by SSE on MRI. There is a linear correlation between SSE and the MD value.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Gan L, Ma J, Feng F, et al. The Predictive Value of Suprasellar Extension for Visual Function Evaluation in Chinese Patients with Nonfunctioning Pituitary Adenoma with Optic Chiasm Compression. World Neurosurg. 2018. PMID: 29857216. doi:10.1016/j.wneu.2018.05.141

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。