文献速递脑血管病外科

细小颅内动脉可良好耐受Y型或重叠方式部署2枚支架治疗颅内动脉瘤

Small Tenuous Intracranial Arteries Can Well Tolerate the Deployment of 2 Stents in Y Configuration or an Overlapping Manner in Treating Intracranial Aneurysms.
PubMed 文献 · World Neurosurg · 2018-06-02

研究纳入15例患者(11女4男,年龄25-83岁)的18个宽颈颅内动脉瘤,采用2枚支架伴或不伴后续弹簧圈栓塞治疗,共部署30枚支架。比较载瘤动脉、单支架与双支架段血管直径及截面积,结果显示双支架段无显著血管狭窄,细小脑动脉可良好耐受2枚支架部署。

要点

  • 15例患者18个宽颈颅内动脉瘤共部署30枚支架,伴或不伴弹簧圈栓塞。
  • 双支架部署后C点和E点平均血管直径及截面积较支架前显著增加。
  • 双支架段与单支架段或原生动脉段相比未见显著血管狭窄。

核心结论

  • 细小颅内动脉可良好耐受部署2枚支架治疗颅内动脉瘤。

研究设计与样本

  • 研究纳入15例患者(11名女性、4名男性;年龄范围25-83岁)的18个宽颈颅内动脉瘤,采用2枚支架伴或不伴后续弹簧圈栓塞治疗,共部署30枚支架。

主要发现

  • 支架前平均血管直径在A点为3.4±0.21 mm、B点为3.06±0.18 mm、C点为3.16±0.21 mm、D点为2.67±0.27 mm、E点为2.56±0.23 mm。
  • 部署2枚支架后,C点平均血管直径增至3.51±0.22 mm(P=0.0006)、截面积增至9.76±1.17 mm2(P=0.001),E点平均血管直径增至2.88±0.32 mm(P=0.01)、截面积增至7.28±1.46 mm2(P=0.02),均较支架前显著增加。
  • 首次血管造影随访时,C点较支架前显著增加至3.42±0.22 mm和9.42±1.37 mm2;第二次血管造影随访时,A点显著增加至3.62±0.45 mm和10.51±2.37 mm2,B点显著增加至3.26±0.24 mm和8.47±1.26 mm2。
  • 双支架段与单支架段或原生动脉段相比,未见显著血管狭窄。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate parent vessel response to deployment of 2 stents for treatment of cerebral aneurysms. METHODS: Fifteen patients (11 women and 4 men; age range, 25-83 years) with 18 wide-necked intracranial aneurysms were treated with 2 stents with or without subsequent coiling. The vascular diameter was measured and compared within the native parent artery, and the single stent and double stent were measured and compared before and immediately after stenting and at angiographic follow-up. RESULTS: Thirty stents were deployed. Before stenting, the mean vessel diameter was 3.4 ± 0.21 mm at point A, 3.06 ± 0.18 mm at point B, 3.16 ± 0.21 mm at point C, 2.67 ± 0.27 mm at point D, and 2.56 ± 0.23 mm at point E. The deployment of 2 stents resulted in statistically significant increases in both the average vascular diameter and cross-sectional area at points C (3.51 ± 0.22 mm, P = 0.0006; and 9.76 ± 1.17 mm2, P = 0.001, respectively) and E (2.88 ± 0.32 mm, P = 0.01; and 7.28 ± 1.46 mm2, P = 0.02, respectively) compared with prestenting. At angiographic follow-ups, compared with before stenting, significant increases were documented at point C (3.42 ± 0.22 mm and 9.42 ± 1.37 mm2, respectively) at first angiographic follow-up but at points A (3.62 ± 0.45 mm and 10.51 ± 2.37 mm2, respectively) and B (3.26 ± 0.24 mm and 8.47±1.26 mm2, respectively) at second angiographic follow-up. No significant vascular stenosis was demonstrated at the double-stent segment compared with the single-stent or native artery segments. CONCLUSIONS: The small tenuous cerebral arteries can well tolerate the deployment of 2 stents for the treatment of intracranial aneurysms.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Li CH, Gao BL, Wang JW, et al. Small Tenuous Intracranial Arteries Can Well Tolerate the Deployment of 2 Stents in Y Configuration or an Overlapping Manner in Treating Intracranial Aneurysms. World Neurosurg. 2018. PMID: 29870849. doi:10.1016/j.wneu.2018.05.179

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。