文献速递脑血管病外科

颅内动脉瘤手术治疗的安全性与有效性:巴西单中心经验

Safety and Efficacy of Surgical Treatment of Intracranial Aneurysms: The Experience of a Single Brazilian Center.
PubMed 文献 · World Neurosurg · 2018-06-20

该研究回顾性分析了2008至2016年间巴西单中心320例患者416个动脉瘤的显微外科夹闭治疗,评估出院时改良Rankin量表(mRS)、术后数字减影血管造影(DSA)及死亡率。结果显示破裂动脉瘤、巨大及大型动脉瘤与不良预后相关,术后DSA显示89.8%完全闭塞,作者认为显微外科治疗安全有效。

要点

  • 320例患者中81例(26.3%)预后不良(mRS>2),227例(73.4%)预后良好。
  • 破裂动脉瘤是不良预后(P<0.001)和死亡(P<0.015)的显著因素。
  • 术后DSA显示207例(89.8%)完全闭塞,24例(10.2%)有残留动脉瘤,8例需再手术。

核心结论

  • 作者认为颅内动脉瘤的显微外科治疗是一种有效且安全的方法。

研究设计与样本

  • 回顾性研究,纳入2008年至2016年间巴西单中心接受显微外科夹闭治疗的320例患者共416个动脉瘤。

主要发现

  • 320例患者中228例为破裂动脉瘤,92例为未破裂动脉瘤;81例(26.3%)预后不良(mRS>2),227例(73.4%)预后良好。
  • 破裂动脉瘤是不良预后(P<0.001)和死亡(P<0.015)的统计学显著因素;巨大及大型动脉瘤也与不良预后相关(P=0.004)。
  • 未破裂动脉瘤中,不良预后仅与动脉瘤大小相关;破裂动脉瘤患者中,入院时Hunt和Hess(HH)分级>2级者预后不良(P<0.0001)。
  • 术后接受DSA检查的患者中,207例(89.8%)完全闭塞,24例(10.2%)有残留动脉瘤,8例需再手术。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The use of microsurgery for aneurysm clipping has decreased considerably in recent years. This study was conducted to demonstrate the safety and effectiveness of surgical treatment of intracranial aneurysms even in less-developed countries. METHODS: This study was a retrospective review of the medical records of 320 patients with 416 aneurysms treated with microsurgical clipping at a single neurosurgical center in Brazil between 2008 and 2016. We evaluated postoperative outcomes using the modified Rankin Scale (mRS) at the time of hospital discharge, treatment efficacy by digital subtraction angiography (DSA) performed postoperatively, and mortality. RESULTS: The 320 patients with aneurysms included 228 patients with ruptured aneurysms and 92 with unruptured aneurysms. Overall, 81 (26.3%) had a poor outcome (mRS score >2), and the other 227 (73.4%) had a good outcome. The presence of a ruptured aneurysm was a statistically significant factor for poor outcome (P < 0.001) and mortality (P < 0.015). Giant and large aneurysms were also associated with poor outcome (P = 0.004). When analyzed separately, unruptured aneurysms with poor outcome were only associated with aneurysm size. Among the patients with ruptured aneurysms, those with Hunt and Hess (HH) grade >2 on hospital admission had unfavorable outcomes (P < 0.0001). Among the patients who underwent postoperative DSA, 207 (89.8%) had complete aneurysm occlusion and 24 (10.2%) had residual aneurysms, with reoperation required in 8 cases. CONCLUSIONS: Microsurgical treatment of intracranial aneurysms is an effective and safe method.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Dellaretti M, Ronconi D, Batista DM, et al. Safety and Efficacy of Surgical Treatment of Intracranial Aneurysms: The Experience of a Single Brazilian Center. World Neurosurg. 2018. PMID: 29935315. doi:10.1016/j.wneu.2018.06.091

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。