文献速递脑血管病外科小儿神经外科与脑积水

Pipeline栓塞装置血流导向治疗儿童患者破裂性大脑后动脉夹层动脉瘤

Pipeline Embolization Device Flow Diversion for a Dissecting Ruptured Posterior Cerebral Artery Aneurysm in a Pediatric Patient.
PubMed 文献 · World Neurosurg · 2018-06-15

本文报告一名4岁既往健康男童因蛛网膜下腔出血就诊,磁共振血管造影提示右侧大脑后动脉破裂性夹层动脉瘤,在与父母讨论后选择超说明书使用Pipeline栓塞装置(PED),于发病24小时内成功置入单枚PED。6个月随访时患者完全恢复,改良Rankin量表评分为0,磁共振血管造影显示动脉瘤完全闭塞且载瘤动脉通畅。作者结论认为,尽管PED未获美国食品药品监督管理局批准用于儿童颅内动脉瘤,文献报告该应用结局良好,PED可能是有挑战性儿童病例的可行选择,但需进一步研究确定该技术是否为儿童动脉瘤可行且持久的治疗选择。

要点

  • 4岁男童右侧大脑后动脉破裂性夹层动脉瘤,发病24小时内超说明书置入单枚Pipeline栓塞装置。
  • 6个月随访改良Rankin量表评分为0,磁共振血管造影示动脉瘤完全闭塞、载瘤动脉通畅。
  • 作者认为PED可能为儿童有挑战性病例的可行选择,但需进一步研究确定其可行性与持久性。

核心结论

  • 尽管PED未获美国食品药品监督管理局批准用于儿童颅内动脉瘤,文献报告该应用结局良好,PED可能是有挑战性儿童病例的可行选择。
  • 需进一步研究来确定该技术是否为儿童动脉瘤可行且持久的治疗选择。

研究设计与样本

  • 病例报告并附文献综述,报告一名4岁既往健康男童的破裂性右侧大脑后动脉夹层动脉瘤。

主要发现

  • 磁共振血管造影提示右侧大脑后动脉破裂性夹层动脉瘤。
  • 于发病24小时内成功置入单枚PED。
  • 6个月随访时患者完全恢复,改良Rankin量表评分为0,磁共振血管造影显示动脉瘤完全闭塞且载瘤动脉通畅。

临床怎么用

  • 作者认为PED可能是有挑战性儿童病例的可行选择,但需进一步研究确定其可行性与持久性。

局限性

  • 需进一步研究来确定该技术是否为儿童动脉瘤可行且持久的治疗选择。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Intracranial aneurysms (IAs) are rare in the pediatric population and are usually considered difficult to treat with traditional microsurgery owing to their complex morphology. Endovascular techniques have become the standard option for treating IAs in adults. More recently, flow diverters, such as the Pipeline embolization device (PED), are being widely adopted for unruptured IAs, with proven safety and efficacy in adults; however, their use in the pediatric population is not well defined. Here we report a pediatric patient with a ruptured posterior cerebral artery (PCA) aneurysm successfully treated with a PED, and provide a review of the literature on the current status of PED use in this subset of patients. CASE DESCRIPTION: A previously healthy 4-year old boy presented to the emergency department with a subarachnoid hemorrhage. Magnetic resonance angiography (MRA) suggested a ruptured dissecting aneurysm in the right PCA. After discussing treatment options with the child's parents, off-label use of the PED device was chosen. A single PED device was successfully deployed within 24 hours of onset. At a 6-month follow-up, the patient was fully recovered, with a modified Rankin Scale score of 0, and MRA showed complete occlusion of the aneurysm and patency of the parent vessel. CONCLUSIONS: Even though the PED has not received Food and Drug Administration approval to treat IAs in children, the literature reports favorable outcomes with this application. Thus, the PED may be a feasible option for treating challenging cases occurring more frequently in the pediatric population. Further studies in pediatric populations are needed to determine whether this technology is a viable and durable option for treating aneurysms in children.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Cunegatto-Braga M, Hogan B, Aguilar-Salinas P, et al. Pipeline Embolization Device Flow Diversion for a Dissecting Ruptured Posterior Cerebral Artery Aneurysm in a Pediatric Patient. World Neurosurg. 2018. PMID: 29909213. doi:10.1016/j.wneu.2018.06.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。