磁敏感加权成像评估未破裂脑动静脉畸形的血管构筑特征
本研究连续纳入81例未破裂脑动静脉畸形患者,以数字减影血管造影为参考标准,评估磁敏感加权成像(SWI)检测血管构筑特征的准确性。结果显示SWI可识别所有病灶,图像质量均至少满足诊断(3-5分),检测深部或后颅窝位置、单纯深静脉引流、静脉扩张、静脉曲张及伴动脉瘤的曲线下面积分别为1、0.93、0.94、0.95和0.83。SWI可能成为血管造影的无创替代技术用于未破裂bAVM的血管构筑评估。
要点
- SWI可识别所有未破裂bAVM病灶,图像质量均至少满足诊断(3-5分)。
- 以DSA为参考,SWI检测深部或后颅窝位置的AUC为1。
- SWI检测单纯深静脉引流、静脉扩张、静脉曲张、伴动脉瘤的AUC分别为0.93、0.94、0.95、0.83。
核心结论
- SWI可能成为血管造影的无创替代技术,用于未破裂bAVM的血管构筑评估。
研究设计与样本
- 连续纳入81例未破裂bAVM患者,以数字减影血管造影为参考标准评估SWI检测血管构筑特征的准确性。
主要发现
- SWI识别所有病灶,两位阅片者判定所有患者图像质量至少满足诊断(范围3-5分)。
- 以DSA为参考,SWI检测深部或后颅窝位置、单纯深静脉引流、静脉扩张、静脉曲张及伴动脉瘤的AUC分别为1、0.93、0.94、0.95和0.83。
- 39例(48.15%)患者SWI检出病灶内沉默性微出血,伴与不伴沉默性微出血者的血管构筑特征无显著差异(P > 0.05)。
关键数值与推荐
- SWI图像质量采用5分法评估,所有患者评分范围为3-5分,至少满足诊断。
- 以DSA为参考标准,SWI检测深部或后颅窝位置的AUC为1。
- 以DSA为参考标准,SWI检测单纯深静脉引流的AUC为0.93。
- 以DSA为参考标准,SWI检测静脉扩张的AUC为0.94。
- 以DSA为参考标准,SWI检测静脉曲张的AUC为0.95。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: A precise assessment of angioarchitectural characteristics using noninvasive imaging is helpful for serial follow-up and weighting risk of natural history in unruptured brain arteriovenous malformation (bAVM). This study aimed to test the hypothesis that susceptibility weighted imaging (SWI) would provide an accurate evaluation of angioarchitectural features of unruptured bAVM. METHODS: A total of 81 consecutive patients with unruptured bAVM were examined. Image quality of SWI for the assessment of bAVM angioarchitectural features was determined by a 5-point scale. The accuracy of SWI for detection of angioarchitectural features was evaluated using digital subtraction angiography as a standard reference and further compared among unruptured bAVMs with or without silent intralesional microhemorrhage on SWI to examine the potential confounding effect of microhemorrhage on image analysis. RESULTS: All lesions were identified on SWI. Image quality of SWI was judged to be at least adequate for diagnosis (range, 3-5) in all patients by both readers. Using digital subtraction angiography as a reference standard, the area under the receiver operating curve of detection of deep or posterior fossa location, exclusively deep venous drainage, venous ectasia, venous varices, and the presence of associated aneurysm on SWI was 1, 0.93, 0.94, 0.95, and 0.83, respectively. Silent intralesional microhemorrhage were detected in 39 patients (48.15%) on SWI and no significant difference (P > 0.05) was found in angioarchitectural features between patients with and without silent microhemorrhage. CONCLUSIONS: SWI might be a noninvasive alternative technique for angiography in the angioarchitectural assessment of unruptured bAVM.
引用
- Wu CX, Ma L, Chen XZ, et al. Evaluation of Angioarchitectural Features of Unruptured Brain Arteriovenous Malformation by Susceptibility Weighted Imaging. World Neurosurg. 2018. PMID: 29859363. doi:10.1016/j.wneu.2018.05.151