微电极记录验证基于7T磁共振成像与机器学习的丘脑底核临床可视化在脑深部电刺激手术中的准确性
本研究纳入16例帕金森病患者(30根电极轨迹),比较基于7T磁共振与机器学习(7T-ML)方法在临床3T磁共振上可视化的丘脑底核与术中微电极记录的一致性。结果显示30根轨迹全部相交于丘脑底核,轨迹长度分别为6.2±0.7 mm与5.8±0.9 mm,触点位置一致率为93%。作者认为7T-ML方法与微电极记录高度一致,可提供可靠且准确的患者个体化丘脑底核靶点预测。
要点
- 16例帕金森病患者共30根电极轨迹,微电极记录与7T-ML方法均显示全部轨迹相交于丘脑底核。
- 丘脑底核轨迹平均长度:微电极记录6.2±0.7 mm,7T-ML方法5.8±0.9 mm。
- 触点位置(背侧、内部或腹侧于丘脑底核)一致率为93%。
核心结论
- 7T-ML方法与微电极记录数据高度一致,可为丘脑底核靶点提供可靠且准确的患者个体化预测。
研究设计与样本
- 研究纳入16例接受微电极记录引导的丘脑底核脑深部电刺激手术的帕金森病患者,共30根植入电极轨迹。
- 比较微电极记录与基于患者临床3T磁共振计算的7T-ML方法所测的丘脑底核轨迹长度及触点位置(背侧、内部或腹侧于丘脑底核)。
主要发现
- 基于微电极记录相交于丘脑底核的全部30根电极轨迹,经7T-ML方法可视化后也均相交于丘脑底核。
- 丘脑底核轨迹平均长度:微电极记录为6.2±0.7 mm,7T-ML方法为5.8±0.9 mm。
- 微电极记录与7T-ML方法在触点位置方面的一致率为93%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a proven and effective therapy for the management of the motor symptoms of Parkinson's disease (PD). While accurate positioning of the stimulating electrode is critical for success of this therapy, precise identification of the STN based on imaging can be challenging. We developed a method to accurately visualize the STN on a standard clinical magnetic resonance imaging (MRI). The method incorporates a database of 7-Tesla (T) MRIs of PD patients together with machine-learning methods (hereafter 7 T-ML). OBJECTIVE: To validate the clinical application accuracy of the 7 T-ML method by comparing it with identification of the STN based on intraoperative microelectrode recordings. METHODS: Sixteen PD patients who underwent microelectrode-recordings guided STN DBS were included in this study (30 implanted leads and electrode trajectories). The length of the STN along the electrode trajectory and the position of its contacts to dorsal, inside, or ventral to the STN were compared using microelectrode-recordings and the 7 T-ML method computed based on the patient's clinical 3T MRI. RESULTS: All 30 electrode trajectories that intersected the STN based on microelectrode-recordings, also intersected it when visualized with the 7 T-ML method. STN trajectory average length was 6.2 ± 0.7 mm based on microelectrode recordings and 5.8 ± 0.9 mm for the 7 T-ML method. We observed a 93% agreement regarding contact location between the microelectrode-recordings and the 7 T-ML method. CONCLUSION: The 7 T-ML method is highly consistent with microelectrode-recordings data. This method provides a reliable and accurate patient-specific prediction for targeting the STN.
引用
- Shamir RR, Duchin Y, Kim J, et al. Microelectrode Recordings Validate the Clinical Visualization of Subthalamic-Nucleus Based on 7T Magnetic Resonance Imaging and Machine Learning for Deep Brain Stimulation Surgery. Neurosurgery. 2019. PMID: 29800386. doi:10.1093/neuros/nyy212
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。