Ⅰ型Chiari畸形患者枕骨大孔区心脏相关脊髓组织运动增加且减压术后降低
研究纳入20例接受减压手术的症状性Ⅰ型Chiari畸形(CM-I)患者和15名健康志愿者,采用相位对比磁共振成像(PC-MRI)测量枕骨大孔(FM)处脊髓运动(SCM)。术前患者组织运动显著大于对照组(P=0.0009),术后运动降低(P=0.058),术后与对照组整体位移无统计学差异(P=0.200)。作者认为SCM测量可能作为CM-I的无创影像学诊断方法。
要点
- 术前CM-I患者枕骨大孔处脊髓组织运动显著大于健康对照(P=0.0009)。
- 减压术后脊髓运动降低(P=0.058),效应量为-0.151 mm,标准误0.066 mm。
- 术后与对照组整体位移无统计学差异(P=0.200),采用Tukey校正多重比较。
核心结论
- 结果支持PC-MRI测量的SCM可能作为CM-I的无创影像学诊断方法。
- SCM动态测量与扁桃体位置静态量化及其他颅内形态学测量一起,为CM-I提供独特诊断信息。
研究设计与样本
- 队列研究:20例症状性CM-I患者接受减压手术,15名健康志愿者作为对照。
- 术前及术后在枕骨大孔处采集轴位相位对比磁共振成像(PC-MRI)测量,采用头尾方向速度编码,每个心动周期20帧,回顾性重建。
- 脊髓运动(SCM)基于平均脊髓速度的峰-峰积分进行量化。
主要发现
- 术前组组织运动显著大于对照组(P=0.0009)。
- 术后运动降低(P=0.058),效应量为-0.151 mm,标准误0.066 mm。
- 术后枕骨大孔处整体位移与对照组无统计学差异(P=0.200),采用Tukey校正多重比较的事后检验。
临床怎么用
- 作者认为PC-MRI测量SCM可能作为CM-I的无创影像学诊断方法,并提供与静态扁桃体位置量化及其他颅内形态学测量互补的诊断信息。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Type 1 Chiari malformation (CM-I) is a craniospinal disorder historically defined by cerebellar tonsillar position greater than 3-5 mm below the foramen magnum (FM). This definition has come under question because quantitative measurements of cerebellar herniation do not always correspond with symptom severity. Researchers have proposed several additional radiographic diagnostic criteria based on dynamic motion of fluids and/or tissues. The present study objective was to determine if cardiac-related craniocaudal spinal cord tissue displacement is an accurate indicator of the presence of CM-I and if tissue displacement is altered with decompression. METHODS: A cohort of 20 symptomatic patients underwent decompression surgery. Fifteen healthy volunteers were recruited for comparison with the CM-I group. Axial phase-contrast magnetic resonance imaging (PC-MRI) measurements were collected before and after surgery at the FM with cranial-caudal velocity encoding and 20 frames per cardiac cycle with retrospective reconstruction. Spinal cord motion (SCM) at the FM was quantified based on the peak-to-peak integral of average spinal cord velocity. RESULTS: Tissue motion for the presurgical group was significantly greater than controls (P = 0.0009). Motion decreased after surgery (P = 0.058) with an effect size of -0.151 mm and a standard error of 0.066 mm. Postoperatively, no statistical difference from controls in bulk displacement at the FM was found (P = 0.200) after post hoc testing using the Tukey adjustment for multiple comparisons. CONCLUSIONS: These results support SCM measurement by PC-MRI as a possible noninvasive radiographic diagnostic for CM-I. Dynamic measurement of SCM provides unique diagnostic information about CM-I alongside static quantification of tonsillar position and other intracranial morphometrics.
引用
- Lawrence BJ, Luciano M, Tew J, et al. Cardiac-Related Spinal Cord Tissue Motion at the Foramen Magnum is Increased in Patients with Type I Chiari Malformation and Decreases Postdecompression Surgery. World Neurosurg. 2018. PMID: 29733988. doi:10.1016/j.wneu.2018.04.191