儿童术中磁共振成像联合术中神经电生理监测的安全性与实用性:一项先导研究
该先导研究纳入2013年10月至2016年4月连续收治的17例接受脑肿瘤手术的儿童,术中同时使用3T术中磁共振成像与体感诱发电位及运动诱发电位监测。术中磁共振成像期间留置483根监测针,观察到2例一度皮肤烧伤,所有患者磁共振成像后监测仍可靠。作者认为该联合方案可安全用于儿童患者。
要点
- 17例患儿术中磁共振成像期间留置483根监测针,发生2例一度皮肤烧伤。
- 所有患者术中磁共振成像后神经电生理监测仍可靠。
- 1例术后运动诱发电位刺激阈值需增加20 mA,2例体感诱发电位波幅较术前下降50%。
核心结论
- 作者认为术中磁共振成像联合术中神经电生理监测可安全用于儿童患者,磁共振成像后监测数据采集可行且仍可靠。
研究设计与样本
- 先导研究,回顾性分析2013年10月至2016年4月连续接受脑肿瘤手术并同时使用3T术中磁共振成像与体感诱发电位、运动诱发电位监测的儿童,共17例。
主要发现
- 30个月期间共17例患儿(平均年龄8.4岁,3例女孩)符合研究标准。
- 术中磁共振成像期间留置483根监测针,其中119根位于头皮、94根位于胸部以上、270根位于胸部以下。
- 观察到2例一度皮肤烧伤并发症。
- 所有患者术中磁共振成像后神经电生理监测仍可靠。
- 1例术中磁共振成像后运动诱发电位刺激阈值需增加20 mA;2例手术结束时体感诱发电位波幅较术中磁共振成像前下降50%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: High-field intraoperative magnetic resonance imaging (MRI) has become increasingly available in neurosurgery centers. There is little experience with combined intraoperative MRI and intraoperative neurophysiologic monitoring (IONM). We report the first series, to our knowledge, of pediatric patients undergoing brain tumor surgery with 3T intraoperative MRI and IONM. METHODS: This pilot study included all consecutive children operated on for brain tumors between October 2013 and April 2016 in whom concomitant intraoperative MRI and somatosensory evoked potentials and motor evoked potentials were used. Neuromonitoring findings and related complications of all cases were retrospectively analyzed. RESULTS: During a 30-month period, 17 children (mean age 8.4 years; 3 girls) undergoing surgery met the study criteria. During intraoperative MRI, 483 IONM needles were left in place. Of these needles, 119 were located on the scalp, 94 were located above the chest, and 270 were located below the chest. Two complications with skin burns (first degree) were observed. In all patients, neuromonitoring was still reliable after MRI. In 1 case, a threshold increase for motor evoked potential stimulation (20 mA) was necessary after intraoperative MRI; in 2 cases, a reduction of 50% of the somatosensory evoked potential amplitude at the end of the surgery was observed compared with the values obtained before intraoperative MRI. CONCLUSIONS: The combination of intraoperative MRI and IONM can be safely used in pediatric patients. IONM data acquisition after intraoperative MRI was feasible and remained reliable.
引用
- Dias S, Sarnthein J, Jehli E, et al. Safeness and Utility of Concomitant Intraoperative Monitoring with Intraoperative Magnetic Resonance Imaging in Children: A Pilot Study. World Neurosurg. 2018. PMID: 29709735. doi:10.1016/j.wneu.2018.04.123
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。