中立位与动态磁共振成像下颈椎管狭窄形态学参数分析
该回顾性研究纳入55例颈椎管狭窄患者,比较中立位、屈曲位和伸展位MRI上压迫层面的脊髓面积、脑脊液面积及脑脊液储备比,并按脊髓高信号有无分组。屈曲位脊髓面积显著小于中立位和伸展位,伸展位脊髓面积较小和屈曲位脑脊液加脊髓面积较小是高信号的预测因素。
要点
- 屈曲位脊髓面积58.8±13.3 mm²,小于中立位66.9±22.3 mm²和伸展位68.3±19.1 mm²。
- 屈曲位与伸展位脑脊液储备比分别为0.47±0.18与0.40±0.21,差异有统计学意义(P<0.05)。
- 伸展位脊髓面积较小(OR 1.46;95%CI 1.07-1.84)和屈曲位脑脊液加脊髓面积较小(OR 1.32;95%CI 1.06-1.45)是高信号预测因素。
核心结论
- 动态MRI显示颈椎管狭窄患者屈曲位、伸展位与中立位的脊髓面积和脑脊液储备比存在显著差异,伸展位脊髓面积较小和屈曲位脑脊液加脊髓面积较小者脊髓高信号风险更大。
研究设计与样本
- 回顾性分析55例(男26例,平均年龄57±13岁)接受中立位、屈曲位和伸展位MRI的颈椎管狭窄患者,比较压迫层面的脊髓面积、脑脊液面积及脑脊液储备比,并按脊髓高信号有无分组,用logistic回归分析高信号的预测因素。
主要发现
- 屈曲位与伸展位脑脊液储备比分别为0.47±0.18与0.40±0.21,差异有统计学意义(P<0.05)。
- 屈曲位脊髓面积58.8±13.3 mm²,小于中立位66.9±22.3 mm²和伸展位68.3±19.1 mm²。
- 22例存在脊髓高信号,其预测因素为伸展位脊髓面积较小(OR 1.46;95%CI 1.07-1.84)和屈曲位脑脊液加脊髓面积较小(OR 1.32;95%CI 1.06-1.45)。
- 受试者工作特征曲线截断值为脊髓面积55 mm²、脑脊液加脊髓面积99 mm²。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: A dynamic compression injury of the cervical spinal cord (SC) is widely accepted in the pathophysiology of cervical myelopathy. Flexion/extension magnetic resonance imaging (MRI) provides information on the dynamic cervical injury. We sought to compare morphometric parameters on neutral and flexion/extension MRI in cervical spondylotic myelopathy. METHODS: Patients with cervical canal stenosis who had MRI in neutral, flexion, and extension positions were reviewed retrospectively. A morphometric comparison of following parameters at compression level was performed: SC area, cerebrospinal fluid (CSF) area, and CSF reserve ratio (CSF/CSF plus SC). Patients were classified according to the presence of high signal (HS) in SC, and predictors of HS were calculated by the use of logistic regression analysis. RESULTS: In total, 55 patients, 26 men, with mean age of 57 ± 13 were analyzed. Significant difference was found in mean CSF reserve ratio between flexion and extension (0.47 ± 0.18 vs. 0.40 ± 0.21, P < 0.05). SC area was significantly smaller in flexion (58.8 ± 13.3 mm2) than in both neutral (66.9 ± 22.3 mm2) and extension (68.3 ± 19.1 mm2). HS was found in 22 cases, and predictors of HS were smaller SC area on extension (odds ratio 1.46; 95% confidence interval 1.07-1.84) and smaller CSF plus SC area on flexion (OR 1.32; 95% confidence interval 1.06-1.45). Cut-off values on the receiver operating characteristic curve were 55 mm2 for SC and 99 mm2 for CSF plus SC area. CONCLUSIONS: Application of dynamic MRI in cervical stenosis reveals significant differences of both SC and CSF reserve ratio in flexion/extension and neutral positions. Patients with smaller SC area in extension and smaller CSF plus SC area in flexion have greater risk of HS on MRI.
引用
- Tykocki T, du Plessis J, Wynne-Jones G, et al. Analysis of Morphometric Parameters in Cervical Canal Stenosis on Neutral and Dynamic Magnetic Resonance Imaging. World Neurosurg. 2018. PMID: 29524700. doi:10.1016/j.wneu.2018.02.179
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。