癫痫持续状态后短暂局灶性磁共振异常在脑海绵状血管畸形患者中显示11C-蛋氨酸正电子发射断层摄取
一例51岁男性脑海绵状血管畸形患者在癫痫持续状态后出现短暂局灶性MRI异常,11C-蛋氨酸PET显示相应病灶高摄取,初诊疑为低级别胶质瘤,术后病理证实为典型海绵状血管畸形,瘤周皮质仅见轻度胶质增生。作者认为短暂局灶性MRI异常可能代表可逆性皮质脑水肿,11C-蛋氨酸PET摄取可在无恶性肿瘤时出现,对脑肿瘤相关癫痫患者应重复影像学检查。
要点
- 癫痫持续状态后可出现短暂局灶性MRI异常,类似胶质瘤。
- 11C-蛋氨酸PET可在无恶性肿瘤的病灶中显示高摄取。
- 对脑肿瘤相关癫痫患者,作者建议重复影像学检查。
核心结论
- 癫痫持续状态后短暂局灶性MRI异常可能提示可逆性皮质脑水肿。
- 即使无恶性肿瘤,相应病灶也可能出现11C-蛋氨酸PET高摄取。
- 作者认为区分癫痫持续状态后短暂MRI异常与胶质瘤困难,对脑肿瘤相关癫痫患者应重复影像学检查。
研究设计与样本
- 个案报道:1例51岁男性脑海绵状血管畸形患者发生癫痫持续状态。
主要发现
- MRI显示局灶性T2/液体衰减反转恢复高信号区。
- 11C-蛋氨酸PET显示相同病灶高摄取。
- 初诊为低级别胶质瘤,但MRI异常短暂且完全消失。
- 手术切除肿瘤,组织学诊断为典型海绵状血管畸形。
- 瘤周脑回病理示轻度胶质增生伴星形细胞增生,无胶质瘤证据。
临床怎么用
- 作者认为对脑肿瘤相关癫痫患者应重复影像学检查。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Transient focal magnetic resonance imaging (MRI) abnormalities after status epilepticus (SE) are rarely seen in patients with benign brain tumors, and the underlying mechanism is still unknown. We report a rare case of cerebral cavernous malformation with transient focal MRI abnormalities around the tumor and accumulation of 11C-methionine on positron emission tomography (PET) after SE. These findings mimicked those of a glioma because the MRI and methionine PET findings were similar. We also speculate about the cause of this phenomenon in relation to pathologic findings of this case. CASE DESCRIPTION: A 51-year-old man suffered from SE. MRI demonstrated a focal T2/fluid-attenuated inversion recovery hyperintense area. 11C-methionine PET showed high accumulation of methionine in the same lesion. The initial diagnosis was low-grade glioma. However, these MRI abnormalities were transient and completely resolved. The patient underwent surgical removal of the tumor, and the histologic diagnosis was typical cavernous malformation. Pathologic findings of the gyrus around the tumor revealed mild gliosis with proliferating astrocytes but no evidence of glioma. CONCLUSIONS: This case suggests that transient focal MRI abnormalities after SE may indicate reversible cortical brain edema. Accumulation of 11C-methionine on PET could occur in the corresponding lesion even if no malignant tumor is present. Because distinguishing transient MRI abnormalities after SE from a glioma is difficult, repeated imaging studies should be performed in patients with brain tumor-related seizures.
引用
- Ishiguro T, Nitta M, Komori T, et al. Transient Focal Magnetic Resonance Imaging Abnormalities After Status Epilepticus Showed 11C-Methionine Uptake with Positron Emission Tomography in a Patient with Cerebral Cavernous Malformation. World Neurosurg. 2018. PMID: 29530707. doi:10.1016/j.wneu.2018.03.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。