表观扩散系数参数对胶质瘤分级的诊断效能
回顾性分析60例疑似胶质瘤患者的扩散张量成像数据,评估FA和ADC参数在区分II级与III级胶质瘤中的诊断效能。最小ADC值在III级与II级组间有显著差异,最佳截断值0.895×10-3 mm2/s时敏感度81.0%、特异度89.1%、准确率86.6%、AUC 0.87。预测诊断方程优于单一最小ADC指标,敏感度90.5%、特异度84.8%、准确率86.6%。
要点
- 最小ADC值在III级与II级胶质瘤组间有显著差异。
- 最小ADC最佳截断值0.895×10-3 mm2/s,AUC 0.87。
- 预测诊断方程敏感度90.5%、准确率86.6%。
核心结论
- 最小ADC值在区分III级与II级胶质瘤方面具有更优的诊断效能,预测诊断方程可能有助于鉴别。
研究设计与样本
- 回顾性分析60例(女30例,男30例;平均年龄45.4岁)疑似胶质瘤并接受ADC图像引导立体定向活检患者的记录。
主要发现
- 定量分析中,III级与II级胶质瘤组间最小ADC值有显著差异。
- 最小ADC最佳截断值0.895×10-3 mm2/s时,鉴别III级与II级胶质瘤的敏感度81.0%、特异度89.1%、阳性预测值77.3%、阴性预测值91.1%、准确率86.6%、AUC 0.87。
- 预测诊断方程优于单一最小ADC指标,敏感度90.5%、特异度84.8%、阳性预测值73.1%、阴性预测值95.1%、准确率86.6%。
关键数值与推荐
- 最小ADC最佳截断值0.895×10-3 mm2/s,敏感度81.0%、特异度89.1%、阳性预测值77.3%、阴性预测值91.1%、准确率86.6%、AUC 0.87。
- 预测诊断方程敏感度90.5%、特异度84.8%、阳性预测值73.1%、阴性预测值95.1%、准确率86.6%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
This study was to evaluate the diagnostic performance of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) parameters derived from diffusion tensor imaging in the differentiation between grade II and III gliomas. The records of 60 patients (30 women, 30 men; mean age, 45.4 years) suspected of having gliomas who underwent an ADC image-guided stereotactic biopsy were retrospectively reviewed. The values of FA and ADC were measured, and the sensitivity, specificity, accuracy and area under the curve (AUC) of those parameters were calculated based on the receiver operating characteristic curve analysis. A predictive diagnostic equation was also constructed and evaluated. Significant differences in minimum ADC values were found in the quantitative analysis between the grade III and II glioma groups. The sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), accuracy and AUC for identifying grade III and II gliomas at the optimum cut-off value of 0.895 × 10-3 mm2/s of minimum ADC were 81.0, 89.1, 77.3, 91.1, 86.6 and 0.87, respectively. The predictive diagnostic equation was superior to the single minimum ADC indicator with a sensitivity of 90.5%, a specificity of 84.8%, a PPV of 73.1%, an NPV of 95.1%, and an accuracy of 86.6%, respectively. The study provides evidence that minimum ADC values have a superior diagnostic performance in differentiating grade III and II gliomas, and the predictive diagnostic equation may be helpful in the differentiation.
引用
- Wang Q, Zhang J, Xu X, et al. Diagnostic performance of apparent diffusion coefficient parameters for glioma grading. J Neurooncol. 2018. PMID: 29574566. doi:10.1007/s11060-018-2841-5