文献速递神经肿瘤

常见原发性脑肿瘤动态11C-甲硫氨酸PET时间-活性曲线特征

Characteristics of time-activity curves obtained from dynamic 11C-methionine PET in common primary brain tumors.
PubMed 文献 · J Neurooncol · 2018-03-21

研究纳入160例脑肿瘤患者(139例胶质瘤、9例脑膜瘤、4例血管母细胞瘤、8例原发性中枢神经系统淋巴瘤),行动态11C-甲硫氨酸PET并构建时间-活性曲线。结果显示曲线模式可分为四种类型,晚期斜率有助于区分含少突胶质成分肿瘤与星形细胞肿瘤,敏感度74.2%、特异度64.9%。

要点

  • 动态MET-PET的时间-活性曲线可分为四种特征类型。
  • 胶质母细胞瘤早期和晚期MET-SUV显著高于间变性星形细胞瘤、弥漫性星形细胞瘤和正常额叶皮质(P<0.05)。
  • 晚期斜率 cutoff 为-0.04 h-1时,区分含少突胶质成分肿瘤与星形细胞肿瘤的敏感度74.2%、特异度64.9%。

核心结论

  • 动态MET-PET研究获得的每种脑肿瘤MET-TAC定量分析有助于无创区分脑肿瘤亚型,尤其是胶质瘤。

研究设计与样本

  • 研究纳入160例脑肿瘤患者,包括139例胶质瘤、9例脑膜瘤、4例血管母细胞瘤和8例原发性中枢神经系统淋巴瘤(PCNSL),采用三维采集模式行动态MET-PET,连续测量肿瘤最大MET标准化摄取值(MET-SUV)并构建时间-活性曲线(TAC),由达峰时间(TTP)和晚期斜率(SLOPE)生成受试者工作特征(ROC)曲线。

主要发现

  • 将MET-TAC分为三相分析MET动力学时,MET-SUV的TAC模式可分为四种特征类型。
  • 胶质母细胞瘤早期和晚期MET-SUV显著高于间变性星形细胞瘤、弥漫性星形细胞瘤和正常额叶皮质(P<0.05)。
  • 含少突胶质成分肿瘤的晚期SLOPE显著低于星形细胞肿瘤(P<0.001)。
  • 以晚期SLOPE cutoff -0.04 h-1区分含少突胶质成分肿瘤与星形细胞肿瘤,诊断准确度为敏感度74.2%、特异度64.9%。
  • ROC曲线下面积为0.731。

关键数值与推荐

  • 晚期SLOPE cutoff -0.04 h-1用于区分含少突胶质成分肿瘤与星形细胞肿瘤时,敏感度74.2%、特异度64.9%,ROC曲线下面积0.731。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The aim of this study was to assess whether dynamic PET with 11C-methionine (MET) (MET-PET) is useful in the diagnosis of brain tumors. METHODS: One hundred sixty patients with brain tumors (139 gliomas, 9 meningiomas, 4 hemangioblastomas and 8 primary central nervous system lymphomas [PCNSL]) underwent dynamic MET-PET with a 3-dimensional acquisition mode, and the maximum tumor MET-standardized uptake value (MET-SUV) was measured consecutively to construct a time-activity curve (TAC). Furthermore, receiver operating characteristic (ROC) curves were generated from the time-to-peak (TTP) and the slope of the curve in the late phase (SLOPE). RESULTS: The TAC patterns of MET-SUVs (MET-TACs) could be divided into four characteristic types when MET dynamics were analyzed by dividing the MET-TAC into three phases. MET-SUVs were significantly higher in early and late phases in glioblastoma compared to anaplastic astrocytoma, diffuse astrocytoma and the normal frontal cortex (P < 0.05). The SLOPE in the late phase was significantly lower in tumors that included an oligodendroglial component compared to astrocytic tumors (P < 0.001). When we set the cutoff of the SLOPE in the late phase to - 0.04 h-1 for the differentiation of tumors that included an oligodendroglial component from astrocytic tumors, the diagnostic accuracy was 74.2% sensitivity and 64.9% specificity. The area under the ROC curve was 0.731. CONCLUSIONS: The results of this study show that quantification of the MET-TAC for each brain tumor identified by a dynamic MET-PET study could be helpful in the non-invasive discrimination of brain tumor subtypes, in particular gliomas.

来源:J Neurooncol,查看原文。版权归原作者所有。

引用

  1. Nomura Y, Asano Y, Shinoda J, et al. Characteristics of time-activity curves obtained from dynamic 11C-methionine PET in common primary brain tumors. J Neurooncol. 2018. PMID: 29564749. doi:10.1007/s11060-018-2834-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。