文献速递神经肿瘤

术后腔FLAIR信号增高预测全切高级别胶质瘤进展

Increasing FLAIR signal intensity in the postoperative cavity predicts progression in gross-total resected high-grade gliomas.
PubMed 文献 · J Neurooncol · 2018-03-21

该回顾性研究纳入45例全切术后接受放化疗的高级别胶质瘤患者,定量分析术后腔与背景的FLAIR信号比值(C-B比值),发现进展患者该比值高于未进展患者(P=0.014),C-B比值预测进展的ROC曲线下面积为0.875,阈值62.3%,灵敏度69.7%,特异度0.84,高信号组PFS和OS均较短。

要点

  • 进展患者术后腔FLAIR C-B比值高于未进展患者(P=0.014)。
  • C-B比值预测肿瘤进展的ROC曲线下面积为0.875,阈值62.3%,灵敏度69.7%,特异度0.84。
  • 高信号组PFS短于低信号组(P=0.004),OS也短于低信号组(P=0.034)。

核心结论

  • 术后腔FLAIR灰度值增高可能作为预测肿瘤进展的影像学标志物。

研究设计与样本

  • 回顾性纳入45例连续的高级别胶质瘤患者,均在全切术后接受放化疗,定量分析术后腔与背景的FLAIR信号强度。

主要发现

  • 进展患者33例,未进展患者12例。
  • 进展患者术后腔与背景的FLAIR信号比值(C-B比值)高于未进展患者(P=0.014)。
  • 进展患者PFS短于未进展患者(P=0.008)。
  • C-B比值预测肿瘤进展的ROC曲线下面积0.875,阈值62.3%,灵敏度69.7%,特异度0.84,约登指数0.50%。
  • 低信号组PFS长于高信号组(P=0.004),高信号组OS短于低信号组(P=0.034)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

To evaluate the prognostic value of fluid-attenuated inversion recovery (FLAIR) signal intensity of postoperative cavity on progression free survival (PFS) and overall survival (OS) in patients with high-grade gliomas (HGG). This study retrospectively enrolled 45 consecutive HGG patients. These patients had chemoradiotherapy after gross-total resection of tumors. Quantitative analysis of the FLAIR signal intensity in postoperative cavity and background was made. We evaluated the threshold value, accuracy, sensitivity, specificity, and survival state with this technique. The patients who progressed and patients who did not progress were 33 and 12 cases separately. The ratio of postoperative cavity and background (C-B) on FLAIR sequence in patients who progressed was higher than that of patients who did not progress (P = 0.014). The PFS of the patients who progressed was shorter than that of patients who did not progress (P = 0.008). The area under ROC curve, threshold, sensitivity, specificity of C-B ratio for predicting tumor progression were 0.875, 62.3, 69.7, 0.84, and 0.50% respectively. The PFS of lower signal group was much longer than that of higher signal group (P = 0.004). The OS of the patients with higher signal was shorter than that of patients with lower signal (P = 0.034). The increase of gray value of FLAIR in postoperative cavity may be used as an imaging marker for predicting tumor progression.

来源:J Neurooncol,查看原文。版权归原作者所有。

引用

  1. Quan GM, Zheng YL, Yuan T, et al. Increasing FLAIR signal intensity in the postoperative cavity predicts progression in gross-total resected high-grade gliomas. J Neurooncol. 2018. PMID: 29564748. doi:10.1007/s11060-018-2758-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。