WEB栓塞装置治疗脑动脉瘤后夹闭作为再治疗策略:病例报告

Clipping as re-treatment strategy after treatment of a cerebral aneurysm with the Woven EndoBridge embolization device: case report.
PubMed 文献 · J Neurosurg · 2018-03-23

一例49岁女性前交通动脉4×3-mm动脉瘤经4×3 WEB装置治疗后复发,采用夹闭再治疗。术中WEB装置柔软可塑、吲哚菁绿血管造影因网架透明易于评估,无严重瘢痕或WEB突出,作者建议选择性病例可考虑夹闭再治疗。

要点

  • WEB装置治疗后动脉瘤复发再治疗是临床挑战。
  • 夹闭术中WEB装置柔软、动脉瘤可操作性好。
  • 作者建议选择性WEB治疗后复发动脉瘤可考虑夹闭。

核心结论

  • 作者建议对颅内血流导向装置治疗后动脉瘤复发的选择性病例可考虑夹闭再治疗。

研究设计与样本

  • 病例报告:一例49岁女性前交通动脉4×3-mm动脉瘤经4×3 WEB装置治疗后复发,行夹闭再治疗。

主要发现

  • 术中WEB装置柔软有弹性,动脉瘤可操作性优于作者既往夹闭弹簧圈栓塞后动脉瘤的经验。
  • 因WEB网架透明,吲哚菁绿血管造影评估易于实施。
  • 术中未见严重瘢痕或WEB突出,使手术更容易且额外并发症风险更低。

临床怎么用

  • 作者建议选择性WEB装置治疗后动脉瘤复发病例可考虑夹闭再治疗。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Recently, treatment of cerebral aneurysms with the Woven EndoBridge (WEB) device has become an established endovascular strategy. However, over time, neurosurgeons and neuroradiologists will be confronted with the challenge of how to treat aneurysm recanalization. The authors report the case of a 49-year-old woman who underwent re-treatment with clipping after the recanalization of a 4 × 3-mm anterior communicating artery aneurysm that had previously been treated using a 4 × 3 WEB device. In contrast to the authors' prior experiences with clipping of previously coiled aneurysms, the WEB device was found to have a responsive softness during clip placement, and the aneurysm was more maneuverable. Moreover, evaluation with indocyanine green angiography was easy to perform because of the transparent mesh of the WEB device. No profound scarring or WEB protrusion was noted during surgery, making the procedure easier and less dangerous with regard to additional complications. The authors suggest that re-treatment via clipping should be considered in select cases of aneurysm recurrence after treatment with an intraaneurysmal flow diverter.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Durner G, Özpeynirci Y, Schmitz B, et al. Clipping as re-treatment strategy after treatment of a cerebral aneurysm with the Woven EndoBridge embolization device: case report. J Neurosurg. 2018. PMID: 29570011. doi:10.3171/2017.10.JNS171528