虚拟弹簧圈栓塞后模型中的高压是颈内动脉瘤栓塞后复发的预测因素
本研究利用50个颈内动脉瘤(7个再通、43个稳定)的栓塞前三维旋转血管造影数据,构建栓塞前模型和虚拟栓塞后模型,通过计算流体动力学分析发现,再通动脉瘤在虚拟栓塞后模型中的弹簧圈表面压力差显著高于稳定动脉瘤(P < .001),且压力差的曲线下面积(0.967)优于其他评估参数。
要点
- 再通动脉瘤在栓塞前模型中流入面积更大、流入率更高(P = .016,.028)。
- 再通动脉瘤在虚拟栓塞后模型中弹簧圈表面压力差更高(P < .001)。
- 压力差的曲线下面积为0.967,优于其他评估参数。
核心结论
- 虚拟栓塞后模型中的压力差可能是栓塞后复发的强预测因素。
研究设计与样本
- 利用50个颈内动脉瘤(7个再通,43个稳定)的栓塞前患者特异性三维旋转血管造影数据,构建栓塞前模型和虚拟栓塞后模型,并进行计算流体动力学分析。
主要发现
- 与稳定动脉瘤相比,再通动脉瘤在栓塞前模型中流入面积更大(P = .016)、流入率更高(P = .028)。
- 再通动脉瘤在虚拟栓塞后模型中弹簧圈表面压力差更高(P < .001)。
- 受试者工作特征分析显示,压力差的曲线下面积(0.967)优于其他评估参数。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Hemodynamic factors play a crucial role in the recurrence of intracranial aneurysms after coiling. However, the strongest factor for predicting recurrence remains unclear because each risk factor has been investigated and reported separately. OBJECTIVE: To clarify the strongest predictor of recurrence with computational fluid dynamics (CFD). METHODS: Using pretreatment patient-specific 3-dimensional rotational angiography data of 50 internal carotid artery (ICA) aneurysms (7 recanalized, 43 stable) treated with endovascular coiling, we created a precoiling model and a virtual postcoiling model produced by manually cutting the aneurysm by the flat plane corresponding to the virtual coil surface. We conducted CFD analysis to investigate inflow dynamics in the precoiling model and pressure difference and wall shear stress on the virtual coil surface. The pressure difference was calculated by subtracting average pressure at the proximal ICA from the maximum pressure at the coil surface and dividing by dynamic pressure at the proximal ICA for normalization. We compared hemodynamic parameters in both models between recanalized and stable aneurysms. RESULTS: Compared with stable aneurysms, recanalized aneurysms showed a significantly larger inflow area and higher inflow rate in the precoiling model (P = .016, .028), and higher pressure difference at the coil surface in the postcoiling model (P < .001). The receiver-operating characteristic analysis showed that the area under the curve value for the pressure difference (0.967) was superior to that of other evaluated parameters. CONCLUSION: The pressure difference in the virtual postcoiling model may be a strong predictor of recurrence after coiling.
引用
- Nambu I, Misaki K, Uchiyama N, et al. High Pressure in Virtual Postcoiling Model is a Predictor of Internal Carotid Artery Aneurysm Recurrence After Coiling. Neurosurgery. 2019. PMID: 29566209. doi:10.1093/neuros/nyy073
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。