文献速递脑血管病外科神经重症

血流导向装置治疗基底动脉尖动脉瘤

Flow Diversion for the Treatment of Basilar Apex Aneurysms.
PubMed 文献 · Neurosurgery · 2018-01-01

这项多中心回顾性研究纳入16例基底动脉尖动脉瘤患者共18次手术,使用Pipeline或FRED装置,中位随访6个月时68.8%的动脉瘤达到完全或近完全闭塞,1例死亡(6.3%),2例轻微并发症(12.5%),作者认为该技术在高度选择的病例中闭塞率可接受。

要点

  • 16例基底动脉尖动脉瘤患者接受18次血流导向装置手术,中位年龄54.5岁。
  • 中位随访6个月,11个动脉瘤(68.8%)达到完全或近完全闭塞。
  • 1例死亡(6.3%)发生于装置置入后出现大脑后动脉及小脑卒中合并蛛网膜下腔出血。

核心结论

  • 血流导向装置治疗基底动脉尖动脉瘤在高度选择的病例中可获得可接受的闭塞率。
  • 无论是直接血流导向还是夹闭或栓塞失败后的补救治疗,改良Rankin量表评分均等于或优于就诊时,该技术是可行的替代或辅助选择。

研究设计与样本

  • 回顾性分析2009年至2016年8家学术机构前瞻性维护的数据库,纳入16例连续患者共16个基底动脉尖动脉瘤,接受18次血流导向装置手术。

主要发现

  • 16例患者中位年龄54.5岁,5个动脉瘤(31.3%)在蛛网膜下腔出血背景下治疗。
  • 7个动脉瘤(43.8%)单用血流导向装置,9个(56.2%)联合弹簧圈栓塞。
  • 中位随访6个月,11个动脉瘤(68.8%)达到完全(100%)或近完全(90%-99%)闭塞。
  • 单用血流导向装置者不完全闭塞较联合弹簧圈栓塞者更常见,部分闭塞患者年龄显著更小。
  • 2个宽颈动脉瘤接受额外血流导向装置联合弹簧圈栓塞的再治疗;1例死亡(6.3%),2例轻微并发症(12.5%)。

临床怎么用

  • 作者认为,对于高度选择的基底动脉尖动脉瘤病例,血流导向装置可作为可行的替代或辅助选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Flow diversion for basilar apex aneurysms has rarely been reported. OBJECTIVE: To assess flow diversion for basilar apex aneurysms in a multicenter cohort. METHODS: Retrospective review of prospectively maintained databases at 8 academic institutions was performed from 2009 to 2016 to identify patients with basilar apex aneurysms treated with flow diversion. Clinical and radiographic data were analyzed. RESULTS: Sixteen consecutive patients (median age 54.5 yr) underwent 18 procedures to treat 16 basilar apex aneurysms with either the Pipeline Embolization Device (Medtronic Inc, Dublin, Ireland) or Flow Redirection Endoluminal Device (Microvention, Tustin, California). Five aneurysms (31.3%) were treated in the setting of subarachnoid hemorrhage. Seven aneurysms (43.8%) were treated with flow diversion alone, while 9 (56.2%) underwent flow diversion and adjunctive coiling. At a median follow-up of 6 mo, complete (100%) and near-complete (90%-99%) occlusion was noted in 11 (68.8%) aneurysms. Incomplete occlusion occurred more commonly in patients treated with flow diversion alone compared to those with adjunctive coiling. Patients with partial occlusion were significantly younger. Retreatment with an additional flow diverter and adjunctive coiling occurred in 2 aneurysms with wide necks. There was 1 mortality in a patient (6.3%) who experienced posterior cerebral artery and cerebellar strokes as well as subarachnoid hemorrhage after the placement of a flow diverter. Minor complications occurred in 2 patients (12.5%). CONCLUSION: Flow diversion for the treatment of basilar apex aneurysms results in acceptable occlusion rates in highly selected cases. Both primary flow diversion and rescue after failed clipping or coiling resulted in a modified Rankin Scale score that was either equal or better than at presentation and the technology represents a viable alternative or adjunctive option.

来源:Neurosurgery,查看原文。版权归原作者所有。

引用

  1. Dmytriw AA, Adeeb N, Kumar A, et al. Flow Diversion for the Treatment of Basilar Apex Aneurysms. Neurosurgery. 2018. PMID: 29529233. doi:10.1093/neuros/nyx628

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。