儿童重型创伤性脑损伤的无创颅内压监测:当前方法的简明更新
本文通过系统检索PubMed、Medline和Cochrane数据库,纳入27篇关于儿童创伤性脑损伤(TBI)的文献,综述了经颅多普勒、视神经鞘直径、耳声发射、近红外光谱、超声造影和定量瞳孔测量等无创颅内压(ICP)监测方法。作者认为经颅多普勒和视神经鞘直径评估是儿童TBI中监测ICP的最佳无创工具,但侵入性监测仍是当前金标准。
要点
- 纳入27篇儿童TBI文献,综述了6种无创ICP监测方法。
- 经颅多普勒和视神经鞘直径评估被认为是监测儿童TBI ICP的最佳无创工具。
- 侵入性监测仍是当前ICP监测的金标准,但其并发症值得关注。
核心结论
- 侵入性监测方法是当前监测ICP的金标准,但其侵入性导致的并发症值得关注。
- 基于文献,经颅多普勒和视神经鞘直径评估是儿童TBI中监测ICP的最佳无创工具。
- 无创ICP监测方法具有高灵敏度、诊断准确性和操作简单的理想特征,其良好结果和发展可能使其成为儿童TBI神经重症监测的未来。
研究设计与样本
- 对PubMed、Medline和Cochrane数据库进行全面文献检索,系统选择并完整审查文章,总结和讨论相关数据。
- 共纳入并审查27篇关于儿童TBI的文章。
主要发现
- 过去几年使用了多种无创ICP监测设备。
- 在儿童TBI中尝试并在此综述的无创方法包括经颅多普勒、视神经鞘直径、耳声发射、近红外光谱、超声造影和定量瞳孔测量。
临床怎么用
- 作者认为经颅多普勒和视神经鞘直径评估是儿童TBI中监测ICP的最佳无创工具。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Traumatic brain injury (TBI) is a leading cause of pediatric morbidity and mortality worldwide and intracranial pressure (ICP) monitoring plays a crucial role in its management. Based on existing literature, we review the current practicing noninvasive ICP monitoring devices and their accuracy in predicting increased ICP in pediatric TBI. METHODS: A thorough literature search was conducted on PubMed, Medline, and the Cochrane database, articles were selected systematically and reviewed completely, and relevant data were summarized and discussed. RESULTS: A total of 27 articles pertaining to pediatric TBI were included and reviewed. We found various modalities of noninvasive ICP monitoring devices used over the last few years. The noninvasive modalities so far attempted in pediatric TBI and so reviewed here are transcranial Doppler, optic nerve sheath diameter, otoacoustic emission, near-infrared spectroscopy, contrast-enhanced ultrasonography, and quantitative pupillometry. CONCLUSIONS: Invasive monitoring methods are the current gold standard for monitoring ICP; however, complications caused by their invasive nature are of concern. Of all the noninvasive methods based on the literature, we found transcranial Doppler and optic nerve sheath diameter assessment to be the best tools to monitor ICP in pediatric TBI. The promising results and developments of noninvasive ICP monitoring modalities with its ideal features of high sensitivity, diagnostic accuracy, and simple acquisition technique may make it the future of neurointensive monitoring in pediatric TBI.
引用
- Narayan V, Mohammed N, Savardekar AR, et al. Noninvasive Intracranial Pressure Monitoring for Severe Traumatic Brain Injury in Children: A Concise Update on Current Methods. World Neurosurg. 2018. PMID: 29524721. doi:10.1016/j.wneu.2018.02.159