磁敏感加权成像与动态磁敏感对比磁共振成像鉴别高级别胶质瘤与原发性中枢神经系统淋巴瘤的准确性:Meta分析
本Meta分析纳入13项研究共704例受试者,评估动态磁敏感对比(DSC)与磁敏感加权成像(SWI)鉴别高级别胶质瘤(HGG)与原发性中枢神经系统淋巴瘤(PCNSL)的诊断效能。DSC的合并敏感度0.94、特异度0.84,SWI的合并敏感度0.92、特异度0.87。Z检验显示DSC与SWI的AUC值无显著差异(P=0.97)。
要点
- DSC鉴别HGG与PCNSL的合并敏感度0.94、特异度0.84,SROC曲线下面积0.9595。
- SWI鉴别HGG与PCNSL的合并敏感度0.92、特异度0.87,SROC曲线下面积0.9608。
- DSC与SWI的AUC值无显著差异(P=0.97),两者诊断准确性高且相近。
核心结论
- 本Meta分析表明,DSC-MRI与SWI在鉴别HGG与PCNSL方面均具有高且相近水平的诊断准确性。
研究设计与样本
- 本Meta分析共纳入13项研究、合计704例受试者,评估DSC与SWI鉴别HGG与PCNSL的诊断效能。
- 研究评估了异质性与阈值效应,并计算敏感度、特异度及汇总受试者工作特征曲线(SROC)下面积。
主要发现
- DSC技术的合并敏感度为0.94、合并特异度为0.84,SROC曲线下面积(AUC)为0.9595,诊断比值比为81.880。
- SWI技术的合并敏感度为0.92、合并特异度为0.87,SROC曲线下面积(AUC)为0.9608,诊断比值比为89.774。
- Z检验显示DSC与SWI的AUC值无显著差异(P=0.97)。
- DSC组(P=0.69)与SWI组(P=0.32)均未观察到明显的发表偏倚。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: It is always a great challenge to distinguish high-grade glioma (HGG) from primary central nervous system lymphoma (PCNSL). We conducted a meta-analysis to assess the performance of dynamic susceptibility contrast (DSC) and susceptibility-weighted imaging (SWI) in differentiating HGGs from PCNSLs. METHODS: Heterogeneity and threshold effect were evaluated, and sensitivity, specificity (SPE), and areas under the summary receiver operating characteristic curve (SROC) were calculated. RESULTS: Thirteen studies with a total of 704 participants were included in this meta-analysis. For the dynamic susceptibility contrast (DSC) technique, the pooled sensitivity and SPE were 0.94 and 0.84, respectively. The area under the curve (AUC) under the SROC was 0.9595, and the diagnostic odds ratio was 81.880. For the susceptibility weighted imaging (SWI) technique, the pooled sensitivity and SPE were 0.92 and 0.87, respectively. The AUC under the SROC was 0.9608, and the diagnostic odds ratio was 89.774. A Z test showed that no significant difference in AUC values between DSC and SWI (P = 0.97) was observed. In addition, no obvious public bias was observed in both the DSC (P = 0.69) and SWI (P = 0.32) groups. CONCLUSIONS: This meta-analysis indicated that both DSC-MRI and SWI have a high and similar level of diagnostic accuracy for differentiating HGGs from PCNSLs.
引用
- Wu Y, Den Z, Lin Y, et al. Accuracy of Susceptibility-Weighted Imaging and Dynamic Susceptibility Contrast Magnetic Resonance Imaging for Differentiating High-Grade Glioma from Primary Central Nervous System Lymphomas: Meta-Analysis. World Neurosurg. 2018. PMID: 29371168. doi:10.1016/j.wneu.2018.01.098
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。