心电图引导脑室心房分流管置入技术:一种有效且经济的技术简化

Electrocardiographic-Guided Technique for Placement of Ventriculoatrial Shunts: A Valid and Cost-Effective Technical Simplification.
PubMed 文献 · World Neurosurg · 2017-10-31

该研究首次报告5例脑积水患者采用心电图(EKG)引导技术放置脑室心房(VA)分流管远端,并经胸部X线验证所有导管尖端均位于正确范围,无操作相关并发症或需更换导管。作者认为EKG引导技术与透视一样准确,但更简单、易得、便宜、安全且经济有效,可能成为VA分流术中确认尖端位置的首选方法。

要点

  • 5例脑积水患者接受EKG引导VA分流,经胸片证实所有导管尖端位于正确范围。
  • 无放射学证据显示操作相关并发症或需更换的导管。
  • 作者认为EKG引导技术可能与透视一样准确,但更简单、易得、便宜、安全且经济有效。

核心结论

  • EKG引导VA分流技术可能与透视一样准确,但更简单、更易获得、更便宜、更安全且更具成本效益。
  • EKG方法可能成为VA分流中标准放射学控制的有效且经济替代方案,并可能成为VA分流术中确认尖端位置的首选方法。

研究设计与样本

  • 首次经验报告,连续5例患者接受EKG引导技术放置VA分流静脉导管,导管尖端位置经标准胸部X线验证。

主要发现

  • 4名男性和1名女性(平均年龄45.4岁)因脑积水接受EKG引导VA分流。
  • 颈内静脉穿刺右侧4例、左侧1例。
  • 经X线证实,所有VA分流尖端均位于正确范围。
  • 无放射学证据显示操作相关并发症或需更换的导管。

临床怎么用

  • 作者认为EKG方法可能成为VA分流中标准放射学控制的有效且经济替代方案,并可能成为VA分流术中确认尖端位置的首选方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Ventriculoatrial (VA) shunt is a routine technique for the treatment of hydrocephalus. The correct position at the superior vena cava-right atrium junction is generally assessed by radiography. We present the first experience of an alternative, nonradiographic technique to assess the distal end of the VA shunts through an electrocardiographic (EKG) method. The technique has developed from the large experience of central venous catheters (CVC) worldwide; the EKG-guided method is a common and validated alternative to standard radiologic control of the location of the tip of any CVC. METHODS: Five consecutive patients underwent VA shunt with venous catheter positioned with the EKG-guided technique. The position of the catheter tip was verified by standard chest radiography. RESULTS: Four men and 1 woman (mean age, 45.4 years) underwent VA shunt for hydrocephalus with the EKG-guided technique. The side of internal jugular vein puncture was the right side in 4 cases and the left side in 1 case. As confirmed by radiography, all VA shunt tips were located within the correct range. There was no radiologic evidence of procedure-related complication or catheters that had to be replaced. CONCLUSIONS: The EKG-guided technique for VA shunts is as accurate as fluoroscopy, but simpler, more readily available, less expensive, safer, and more cost effective. It reduces the need of radiography and radiologic exposition for both patients and operators. The EKG method may be a valid and cost-effective alternative to standard radiologic control in VA shunts, as for any central venous access device, and could become the preferential method for confirming tip position during VA shunt surgery.

来源:World Neurosurg,查看原文。版权归原作者所有。