文献速递功能神经外科

平板探测器CT评估脑内血管用于立体定向脑电图电极植入规划

Flat-Detector Computed Tomography for Evaluation of Intracerebral Vasculature for Planning of Stereoelectroencephalography Electrode Implantation.
PubMed 文献 · World Neurosurg · 2017-11-22

本研究采用平板探测器CT(FD-CT)经选择性动脉内碘对比剂注射获取毛细血管期脑血管解剖,并与薄层MRI融合用于立体定向脑电图(sEEG)电极轨迹规划。39例患者共植入541根电极,25例(64.1%)植入70根斜行岛叶电极,术后无临床显著并发症;36例(92.3%)接受手术干预,其中27例(69.2%)行手术切除。

要点

  • FD-CT联合薄层MRI融合可规划sEEG复杂轨迹,包括高斜度岛叶电极与经「空沟」经沟轨迹。
  • 39例患者共植入541根电极,25例(64.1%)植入70根斜行岛叶电极,术后无临床显著并发症。
  • 36例(92.3%)接受手术干预,其中27例(69.2%)行手术切除。

核心结论

  • FD-CT通过毛细血管期可详细显示皮质脑血管解剖及颅骨解剖,使复杂轨迹的安全规划成为可能,并同时提供骨性解剖影像以用于术前规划钻深与锚定放置。

研究设计与样本

  • 所有患者术前接受FD-CT,经选择性动脉内碘对比剂注射,采集晚动脉期与毛细血管期以评估脑血管解剖,结果与薄层MRI融合用于颅内sEEG电极轨迹规划。
  • 所有患者电极置入后接受常规CT与MRI检查。

主要发现

  • 39例患者按此方案接受sEEG植入,共植入541根电极。
  • 25例(64.1%)患者植入70根斜行岛叶电极。
  • 电极植入后无临床显著并发症。
  • 36例(92.3%)患者接受手术干预,其中27例(69.2%)行手术切除。

临床怎么用

  • 作者认为FD-CT可详细显示皮质脑血管解剖与颅骨解剖,可用于规划包括高斜度岛叶电极和经「空沟」经沟轨迹在内的复杂轨迹,并同时用于术前规划钻深与锚定放置。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Stereoelectroencephalography (sEEG) requires extensive preoperative planning to optimize placement of electrodes and limit the potential for complications. Flat-detector computed tomography (FD-CT) has previously been used for perioperative vascular imaging to guide the treatment of vascular lesions. This imaging modality provides a detailed depiction of cerebrovascular and bony cranial anatomy, which can be used to guide intracranial electrode implantation. We have developed a novel method to improve preoperative planning for sEEG electrode implantation and limit the potential for postoperative complications by using FD-CT imaging merged with preoperative magnetic resonance imaging (MRI). METHODS: All patients underwent preoperative FD-CT with selective intra-arterial iodinated contrast dye injection through the late arterial and capillary phases for evaluation of cerebrovascular anatomy. These results were merged with thin-cut MRI for trajectory planning of intracranial sEEG electrodes. All patients underwent routine CT and MRI after electrode placement. RESULTS: 39 patients have undergone sEEG implantation according to this protocol, with a total of 541 electrodes placed. Additionally, 25 (64.1%) patients underwent implantation of 70 oblique insular electrodes. There were no clinically significant complications after the implantations. Thirty-six (92.3%) patients underwent operative intervention, including surgical resection in 27 (69.2%) patients. CONCLUSION: FD-CT imaging allows for a detailed depiction of cortical cerebrovascular anatomy through the capillary phase, in addition to bony cranial anatomy. This enables the safe planning of complex trajectories, including high-obliquity insular electrodes and transsulcal trajectories through "empty sulci" while also providing concurrent imaging of bony anatomy to allow for preoperative planning of drill depth and anchor placement.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Schmidt RF, Lang MJ, Hoelscher CM, et al. Flat-Detector Computed Tomography for Evaluation of Intracerebral Vasculature for Planning of Stereoelectroencephalography Electrode Implantation. World Neurosurg. 2017. PMID: 29175567. doi:10.1016/j.wneu.2017.11.063

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。