利用编辑活体磁共振波谱高特异性判定IDH状态
研究前瞻性纳入24例疑似低级别胶质瘤受试者,在3T场强下采用MEGA-PRESS编辑MRS与优化PRESS检测2-羟基戊二酸(2HG),并与DNA测序和组织2HG分析比较。编辑MRS检测2HG的敏感性和特异性均为100%,其估算2HG水平与组织样本一致;优化PRESS性能较低。作者认为编辑MRS是無创预测IDH突变的可靠工具,整合入临床可能对胶质瘤無创诊断、预后评估和治疗计划有益。
要点
- 编辑MRS检测2HG的敏感性和特异性均为100%。
- 编辑MRS估算的2HG水平与组织样本所测水平一致。
- 优化PRESS检测2HG的性能较低,与既往研究发现一致。
核心结论
- 编辑MRS是无创预测IDH突变的可靠工具之一,检测2HG具有高敏感性和特异性。
- 将编辑MRS整合入临床实践可能对胶质瘤的无创诊断、预后评估和治疗计划高度有益。
研究设计与样本
- 前瞻性纳入24例疑似低级别胶质瘤受试者。
- 所有受试者在3T场强下采集MRS数据,采用两种MRS方法:MEGA-PRESS编辑MRS和针对2HG检测优化的PRESS序列,感兴趣体积大于6 mL。
- IDH突变状态通过自动免疫组化分析与Sanger测序联合确定。
- 组织样本2HG水平采用气相色谱-质谱法测定,并与MRS估算值比较。
主要发现
- 编辑MRS检测2HG的敏感性为100%,特异性为100%。
- 编辑MRS估算的2HG水平与组织样本所测水平一致。
- 优化PRESS检测2HG的性能较低,与既往研究发现一致。
临床怎么用
- 作者认为将编辑MRS整合入临床实践可能对胶质瘤的无创诊断、预后评估和治疗计划高度有益。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Mutations in the isocitrate dehydrogenase (IDH) enzyme affect 40% of gliomas and represent a major diagnostic and prognostic marker. The goals of this study were to evaluate the performance of noninvasive magnetic resonance spectroscopy (MRS) methods to determine the IDH status of patients with brain gliomas through detection of the oncometabolite 2-hydroxyglutarate (2HG) and to compare performance of these methods with DNA sequencing and tissue 2HG analysis. METHODS: Twenty-four subjects with suspected diagnosis of low-grade glioma were included prospectively in the study. For all subjects, MRS data were acquired at 3T using 2 MRS methods, edited MRS using Mescher-Garwood point-resolved spectroscopy (MEGA-PRESS) sequence and a PRESS sequence optimized for 2HG detection, using a volume of interest larger than 6 mL. IDH mutational status was determined by a combination of automated immunohistochemical analysis and Sanger sequencing. Levels of 2HG in tissue samples measured by gas chromatography-mass spectrometry were compared with those estimated by MRS. RESULTS: Edited MRS provided 100% specificity and 100% sensitivity in the detection of 2HG. The 2HG levels estimated by this technique were in line with those derived from tissue samples. Optimized PRESS provided lower performance, in agreement with previous findings. CONCLUSIONS: Our results suggest that edited MRS is one of the most reliable tools to predict IDH mutation noninvasively, showing high sensitivity and specificity for 2HG detection. Integrating edited MRS in clinical practice may be highly beneficial for noninvasive diagnosis of glioma, prognostic assessment, and treatment planning.
引用
- Branzoli F, Di Stefano AL, Capelle L, et al. Highly specific determination of IDH status using edited in vivo magnetic resonance spectroscopy. Neuro Oncol. 2018. PMID: 29126125. doi:10.1093/neuonc/nox214
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。