文献速递脑血管病外科神经重症

使用血流导向栓塞装置血管内治疗破裂椎基底动脉夹层动脉瘤:单机构经验

Endovascular Treatment of Ruptured Vertebrobasilar Dissecting Aneurysms Using Flow Diversion Embolization Devices: Single-Institution Experience.
PubMed 文献 · World Neurosurg · 2017-10-05

该单机构回顾性研究从前瞻性登记中识别3年内9例破裂后循环夹层动脉瘤患者,采用血流导向装置及特定急性抗血小板方案治疗,无术中并发症,2例出现无症状脑实质出血,1例因左心室辅助装置额外抗凝后发生大面积脑实质出血并死亡,作者认为该治疗可行且为去构造技术的潜在替代方案。

要点

  • 9例破裂后循环夹层动脉瘤接受血流导向装置治疗,无术中并发症。
  • 8例术后接受替罗非班维持输注(无负荷量),多数术后负荷双联抗血小板。
  • 2例监测CT发现无症状脑实质出血,1例因额外抗凝后大面积出血死亡。

核心结论

  • 作者认为使用血流导向装置治疗破裂后循环夹层动脉瘤可行,且为去构造技术的潜在替代方案。

研究设计与样本

  • 回顾性研究,从前瞻性登记中识别3年期间接受治疗的破裂夹层动脉瘤患者,共9例。

主要发现

  • 9例中5例为椎动脉、2例为基底动脉、2例为小脑后下动脉动脉瘤,平均世界神经外科医师联盟评分为2分(范围1-5分)。
  • 7例因脑积水急性期放置脑室外引流,8例在血流导向装置置入后接受替罗非班维持输注(无负荷量),无术中并发症。
  • 2例在监测非增强CT上发现无症状脑实质出血,1例因左心室辅助装置开始额外抗凝后发生大面积脑实质出血并于干预后数日死亡。
  • 12个月内随访改良Rankin量表评分为0分3例、1分3例、2分1例、4分1例。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Treatment of ruptured posterior circulation dissecting aneurysms is technically challenging with potentially high morbidity and mortality. We sought to assess the safety and feasibility of using a flow-diversion device (FDD) and a specific acute antiplatelet aggregation protocol in the management of ruptured dissecting aneurysms. METHODS: Subjects with ruptured dissecting aneurysms treated during a 3-year period were retrospectively identified from a prospective registry. Intraoperative complications, morbidity, and mortality were recorded. Tirofiban maintenance infusion without bolus was administered intravenously immediately after deployment of the FDD, and almost all patients were loaded with dual antiplatelet (aspirin and clopidogrel) post procedure. Clinical follow-up evaluation and modified Rankin Scale were assessed. RESULTS: Nine subjects with ruptured posterior circulation dissecting aneurysms were treated with an FDD: 5 vertebral artery, 2 basilar artery, and 2 posterior inferior cerebellar artery aneurysms. Average World Federation of Neurosurgical Societies score was 2 (range 1-5). Seven patients had external ventricular drain placed acutely for hydrocephalus. Eight patients received tirofiban infusion without bolus after FDD. No intraoperative complications occurred. Two subjects developed asymptomatic intraparenchymal hemorrhage found on surveillance noncontrast computed tomography. One subject suffered a major intraparenchymal hemorrhage and died a few days post intervention after additional anticoagulation was started for a left ventricular assist device. Follow-up modified Rankin Scale within 12 months was 0 in 3 subjects, 1 in 3 subjects, 2 in 1 subject, and 4 in 1. CONCLUSIONS: Treatment of dissecting posterior circulation aneurysms with FDDs is feasible and a potential alternative to deconstructive techniques.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Guerrero WR, Ortega-Gutierrez S, Hayakawa M, et al. Endovascular Treatment of Ruptured Vertebrobasilar Dissecting Aneurysms Using Flow Diversion Embolization Devices: Single-Institution Experience. World Neurosurg. 2017. PMID: 28987840. doi:10.1016/j.wneu.2017.09.125

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。