经口减压与定制植入物稳定上颈椎在颅颈交界区多种病变中的应用
本文报告5例因颅底及颅颈交界区病变导致寰枢椎不稳并伴脑干前方压迫的患者,采用经口减压及定制固定系统行C1-C2(4例)或C1-C3(1例前后路稳定)前路稳定。所有病例均实现病变完全切除、上颈髓减压及可靠稳定,随访1至4年未见植入物移位或不稳定。作者认为该前路固定系统可安全地作为标准后路稳定方法的替代或联合方案。
要点
- 经口减压联合定制C1-C2或C1-C3前路固定系统可用于颅颈交界区病变的切除与稳定。
- 5例中4例行C1-C2固定,1例行C1-C3前后路稳定,均实现病变全切与上颈髓减压。
- 随访1至4年未见植入物移位或不稳定,未固定的C0-C1及下颈椎节段保留了部分活动度。
核心结论
- 作者首次使用定制C1-C2和C1-C3前路固定系统的经验显示其有效,可安全地作为标准后路稳定方法的替代或联合方案。
研究设计与样本
- 本文报告5例临床病例,采用经口减压及定制固定系统行C1-C2(4例)或C1-C3(1例前后路稳定)前路稳定,治疗颅颈交界区多种病变。
主要发现
- 所有病例均实现病变完全切除、上颈髓减压及上颈椎可靠稳定。
- 4例未固定C0-C1和C3-C7节段,1例未固定C0-C1和C4-C7节段,所有患者均保留了部分颈椎活动度。
- 所有病例均未观察到植入物移位或不稳定,随访时间为术后1至4年。
临床怎么用
- 作者认为该前路固定方法可安全地作为标准后路稳定方法的替代或与后路稳定联合使用。
- 作者指出在其外科实践中开发并实施的这一创新手术技术可优化手术技术、减少围手术期并发症、消除颈椎活动受限、改善运动活动并使患者更早康复。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Surgical treatment of patients with atlantoaxial instability caused by pathologic changes of the skull base and craniovertebral junction combined with anterior compression of the brain stem is still associated with substantial technical difficulties and remains a matter of debate. Currently, anterior stabilization of the atlantoaxial junction is a promising approach that allows for the resection of the pathologic lesion of the skull base and craniovertebral junction with subsequent stabilization of C1-C2 or C1-C3 in 1 stage. METHODS: In this article, we present 5 clinical cases in which transoral decompression and anterior stabilization of the C1-C2 (4 cases) and C1-C3 (1 case of anteroposterior stabilization) segments with custom-made fixation systems was used to treat various pathologic conditions of the craniovertebral junction. RESULTS: In all cases, complete removal of the pathologic lesion and decompression of the upper cervical spinal cord as well as reliable stabilization of the upper spinal segments were achieved. Some degree of movement in the cervical spine was preserved in all patients due to unfixed C0-C1 and C3-C7 segments in 4 cases and C0-C1 and C4-C7 in 1 case. Implant migration or instability was not observed in any of the cases. The follow-up period was from 1 to 4 years after surgery. CONCLUSIONS: The first experience of anterior fixation using individually manufactured C1-C2 and C1-C3 systems demonstrated their effectiveness. This approach can be safely used as an alternative or in combination with standard posterior stabilization methods. An innovative surgical technology developed and implemented in our surgical practice allows for optimization of the surgical technique, reduces the number of perioperative complications, eliminates movement restrictions in the cervical spine, improves motor activity, and makes earlier patient rehabilitation possible.
引用
- Shkarubo AN, Kuleshov AA, Chernov IV, et al. Transoral Decompression and Stabilization of the Upper Cervical Segments of the Spine Using Custom-Made Implants in Various Pathologic Conditions of the Craniovertebral Junction. World Neurosurg. 2017. PMID: 28962950. doi:10.1016/j.wneu.2017.09.124
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。