文献速递神经肿瘤脑血管病外科

类似三维稳态构成干扰序列增强三维时间飞跃磁共振血管造影在岛叶胶质瘤中勾勒豆纹动脉的效用:48例患者前瞻性临床放射学分析证据

Analogous Three-Dimensional Constructive Interference in Steady State Sequences Enhance the Utility of Three-Dimensional Time of Flight Magnetic Resonance Angiography in Delineating Lenticulostriate Arteries in Insular Gliomas: Evidence from a Prospective Clinicoradiologic Analysis of 48 Patients.
PubMed 文献 · World Neurosurg · 2017-10-07

前瞻性纳入48例岛叶胶质瘤患者,联合对比增强冠状位三维时间飞跃磁共振血管造影与冠状位三维稳态构成干扰序列定位豆纹动脉及其与肿瘤关系。联合序列在47例中清晰显示豆纹动脉-肿瘤界面,豆纹动脉被包绕组6例(12.5%)出现术后偏瘫,其中2例(4.2%)归因于豆纹动脉损伤。

要点

  • 对比增强三维时间飞跃可显示几乎所有岛叶胶质瘤的豆纹动脉,但识别豆纹动脉-肿瘤界面有限。
  • 加用三维稳态构成干扰序列可克服上述限制,无论肿瘤信号强度如何均能勾勒界面。
  • 联合序列有助于手术规划与更安全切除,作为术中辅助可能具有额外手术相关性。

核心结论

  • 对比增强三维时间飞跃可勾勒几乎所有岛叶胶质瘤的豆纹动脉,但在识别豆纹动脉-肿瘤界面方面有限。
  • 加用类似三维稳态构成干扰序列可克服该限制,无论肿瘤信号强度如何均能勾勒豆纹动脉-肿瘤界面。
  • 联合三维时间飞跃与三维稳态构成干扰序列是手术规划和更安全切除岛叶肿瘤的有用工具,作为术中辅助可能具有额外手术相关性。

研究设计与样本

  • 前瞻性评估连续48例岛叶胶质瘤患者,为期3年。
  • 采用对比增强冠状位三维时间飞跃磁共振血管造影联合冠状位三维稳态构成干扰序列确定豆纹动脉位置及其与肿瘤关系。
  • 分析上述发现与肿瘤切除范围及早期术后运动结局的关系。

主要发现

  • T1低信号肿瘤患者中29例(60.4%)使用三维时间飞跃清晰显示肿瘤,而使用稳态构成干扰序列所有患者均清晰显示肿瘤。
  • 联合三维时间飞跃与稳态构成干扰序列后,47例患者豆纹动脉-肿瘤界面显示良好,包括所有T1等信号或T1混杂信号肿瘤患者。
  • 豆纹动脉被推挤组切除范围高于豆纹动脉被包绕组。
  • 豆纹动脉被包绕组中6例(12.5%)患者出现术后偏瘫,其中2例(4.2%)归因于豆纹动脉损伤。

临床怎么用

  • 联合三维时间飞跃与三维稳态构成干扰序列可用于岛叶胶质瘤手术规划及更安全切除。
  • 作者认为该联合序列作为术中辅助可能具有额外手术相关性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Three-dimensional (3D) time of flight (TOF) imaging is the current gold standard for noninvasive, preoperative localization of lenticulostriate arteries (LSAs) in insular gliomas; however, the utility of this modality depends on tumor intensity. METHODS: Over a 3-year period, 48 consecutive patients with insular gliomas were prospectively evaluated. Location of LSAs and their relationship with the tumor were determined using a combination of contrast-enhanced coronal 3D TOF magnetic resonance angiography and coronal 3D constructive interference in steady state (CISS) sequences. These findings were analyzed with respect to extent of tumor resection and early postoperative motor outcome. RESULTS: Tumor was clearly visualized in 29 (60.4%) patients with T1-hypointense tumors using 3D TOF and in all patients using CISS sequences. Using combined 3D TOF and CISS, LSA-tumor interface was well seen in 47 patients, including all patients with T1-heterointense or T1-isointense tumors. Extent of resection was higher in the LSA-pushed group compared with the LSA-encased group. In the LSA-encased group, 6 (12.5%) patients developed postoperative hemiparesis; 2 (4.2%) cases were attributed to LSA injury. CONCLUSIONS: Contrast-enhanced 3D TOF can delineate LSAs in almost all insular gliomas but is limited in identifying the LSA-tumor interface. This limitation can be overcome by addition of analogous CISS sequences that delineate the LSA-tumor interface regardless of tumor intensity. Combined 3D TOF and 3D CISS is a useful tool for surgical planning and safer resections of insular tumors and may have added surgical relevance when included as an intraoperative adjunct.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Rao AS, Thakar S, Sai Kiran NA, et al. Analogous Three-Dimensional Constructive Interference in Steady State Sequences Enhance the Utility of Three-Dimensional Time of Flight Magnetic Resonance Angiography in Delineating Lenticulostriate Arteries in Insular Gliomas: Evidence from a Prospective Clinicoradiologic Analysis of 48 Patients. World Neurosurg. 2017. PMID: 29017985. doi:10.1016/j.wneu.2017.09.199

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。