时间-空间标记反转脉冲磁共振成像诊断外部性脑积水的新应用
本文报告一例81岁男性左侧颞叶肿瘤切除并植入Gliadel wafer后3周出现意识障碍及硬膜下积液,脑脊液检查示白细胞计数升高且嗜酸性粒细胞占比超过90%,经时间-空间标记反转脉冲磁共振成像(time-SLIP MRI)检出脑脊液经切除腔流出,诊断为Gliadel诱导的嗜酸性粒细胞性脑膜炎所致外部性脑积水,手术取出Gliadel wafer并置入脑室腹膜分流管后症状改善。
要点
- time-SLIP MRI可无创检出脑脊液经切除腔流出,用于诊断外部性脑积水。
- 本例硬膜下积液由Gliadel诱导的嗜酸性粒细胞性脑膜炎所致外部性脑积水引起。
- 取出Gliadel wafer并置入脑室腹膜分流管后患者症状改善。
核心结论
- 在本例中,time-SLIP MRI是诊断由Gliadel诱导的嗜酸性粒细胞性脑膜炎所致外部性脑积水的有用且无创的方法。
研究设计与样本
- 个案报告:一例81岁男性左侧颞叶肿瘤切除并植入Gliadel wafer后出现硬膜下积液的病例。
主要发现
- 术后3周患者出现意识障碍,计算机断层扫描显示硬膜下积液。
- time-SLIP MRI检出脑脊液经切除腔流出。
- 脑脊液检查显示白细胞计数升高和蛋白水平升高,其中嗜酸性粒细胞占白细胞计数90%以上。
- 组织学检查显示Gliadel wafer周围嗜酸性粒细胞聚集。
- 置入脑室腹膜分流管后患者症状改善。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although a subdural fluid collection frequently is observed, diagnostic methods that differentiate between the subdural collection caused by external hydrocephalus and that caused by subdural hygroma have not been established. Here, we report a case of external hydrocephalus caused by Gliadel-induced eosinophilic meningitis that has been previously reported in only 1 case and can be diagnosed by time-spatial labeling inversion pulse magnetic resonance imaging (time-SLIP MRI). CASE DESCRIPTION: A tumor located in the left temporal was detected incidentally in an 81-year-old man by examination of a head injury. The tumor was surgically resected and diagnosed as a high-grade glioma during the surgery; Gliadel wafers subsequently were implanted. Three weeks after the resection, the patient showed disturbed consciousness, and computed tomography revealed a subdural fluid collection. The out-flow of cerebrospinal through the resection cavity was detected by time-SLIP MRI. Cerebrospinal tests indicated high white blood cell counts and high protein levels, with more than 90% of the white blood cell count comprising eosinophils. Therefore, we suspected that the subdural fluid collection was caused by external hydrocephalus because of Gliadel-induced eosinophilic meningitis. We surgically removed the Gliadel wafers and subsequently performed a surgery to insert a ventriculoperitoneal shunt. Histologic examination indicated eosinophilic accumulation around the Gliadel wafers. The patient's symptoms improved after the insertion of a ventriculoperitoneal shunt. CONCLUSIONS: In the present case, time-SLIP MRI was a useful and noninvasive method for diagnosing external hydrocephalus which was caused by eosinophilic meningitis because of Gliadel-induced eosinophilic meningitis.
引用
- Nakae S, Murayama K, Adachi K, et al. Novel Application of Time-Spatial Labeling Inversion Pulse Magnetic Resonance Imaging for Diagnosis of External Hydrocephalus. World Neurosurg. 2017. PMID: 28989050. doi:10.1016/j.wneu.2017.09.175
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。