主动脉内球囊反搏期间经颅多普勒波形用于蛛网膜下腔出血后血管痉挛检测
该研究回顾性分析4例蛛网膜下腔出血患者中31对同日经颅多普勒与血管造影配对,评估经颅多普勒波形特征与血管痉挛的相关性,发现新特征「速度差」与近端血管痉挛相关,而平均速度、收缩期速度及球囊反搏增强速度与近端血管痉挛无显著相关。
要点
- 新特征「速度差」与近端血管痉挛相关(系数 -6.8,95%CI -9.8至-3.8,P < .001)。
- 平均速度、收缩期速度及球囊反搏增强速度与近端血管痉挛无显著相关。
- 该研究为回顾性研究,样本量小(4例患者,31对配对)。
核心结论
- 「速度差」这一新型经颅多普勒血流速度特征可能反映接受主动脉内球囊反搏的蛛网膜下腔出血患者的血管痉挛。
研究设计与样本
- 回顾性分析接受同日经颅多普勒超声和血管造影的蛛网膜下腔出血病例,共4例患者、31对经颅多普勒与血管造影配对(12对CT血管造影/19对数字减影血管造影)。
主要发现
- 31对配对中14对经血管造影诊断近端血管痉挛。
- 「速度差」与近端血管痉挛相关(系数 -6.8 [95% CI -9.8 to -3.8],P < .001)。
- 平均速度与近端血管痉挛无显著相关(系数 -13.0 [95% CI -29.3 to 3.4],P = .12)。
- 收缩期速度与近端血管痉挛无显著相关(系数 -8.7 [95% CI -24.8 to 7.3],P = .29)。
- 球囊反搏增强速度与近端血管痉挛无显著相关(系数 -15.3 [95% CI -31.3 to 0.71],P = .06)。
局限性
- 该研究为回顾性研究,样本量小(4例患者,31对配对)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Transcranial Doppler ultrasound is a standard screening tool for vasospasm after subarachnoid hemorrhage. Prevention of vasospasm-induced delayed cerebral ischemia after subarachnoid hemorrhage depends on optimization of cerebral perfusion pressure, which can be challenged by neurogenic stress cardiomyopathy. Intra-aortic balloon pumps have been utilized to augment cerebral perfusion, but they change the transcranial Doppler waveform, altering its interpretability for vasospasm screening. OBJECTIVE: To assess the features of the transcranial Doppler waveform that correlate with vasospasm. METHODS: We retrospectively reviewed cases of subarachnoid hemorrhage that underwent same-day transcranial Doppler ultrasound and angiography. Transcranial Doppler waveforms were assessed for mean velocity, peak systolic velocity, balloon pump-augmented diastolic velocity, and a novel feature, "delta velocity" (balloon pump-augmented velocity - systolic velocity). Relationship of flow velocity features to vasospasm was estimated by generalized estimating equation models using a Gaussian distribution and an exchangeable correlation structure. RESULTS: There were 31 transcranial Doppler and angiography pairings (12 CT angiography/19 digital subtraction angiography) from 4 patients. Fourteen pairings had proximal vasospasm by angiography. Delta velocity was associated with proximal vasospasm (coefficient -6.8 [95% CI -9.8 to -3.8], P < .001). There was no significant correlation with proximal vasospasm for mean velocity (coefficient -13.0 [95% CI -29.3 to 3.4], P = .12), systolic velocity (coefficient -8.7 [95% CI -24.8 to 7.3], P = .29), or balloon pump-augmented velocity (coefficient -15.3 [95% CI -31.3 to 0.71], P = .06). CONCLUSION: Delta velocity, a novel transcranial Doppler flow velocity feature, may reflect vasospasm in patients with subarachnoid hemorrhage and intra-aortic balloon pumps.
引用
- Morris NA, Manning N, Marshall RS, et al. Transcranial Doppler Waveforms During Intra-aortic Balloon Pump Counterpulsation for Vasospasm Detection After Subarachnoid Hemorrhage. Neurosurgery. 2018. PMID: 28973669. doi:10.1093/neuros/nyx405
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。