创伤性脑损伤去骨瓣减压术后氙增强CT定量脑血流研究
本研究评估创伤性脑损伤去骨瓣减压术后患者全局与区域脑血流模式及其与脑血流动力学参数和早期临床结局的关系。27例患者去骨瓣减压术后行氙增强CT脑血流检查,出院时死亡患者骨窗下皮质脑血流显著低于存活患者(30.1±22.9 vs 50.6±19.6 ml/100 g/min;p=0.039),且脑灌注压显著更低(52±17.4 vs 75.3±10.9 mm Hg;p=0.001)。
要点
- 去骨瓣减压术后全局脑血流均值为49.9±21.3 ml/100 g/min。
- 出院时死亡患者骨窗下皮质脑血流显著低于存活患者(p=0.039)。
- 死亡患者脑灌注压显著低于存活患者(52±17.4 vs 75.3±10.9 mm Hg;p=0.001)。
核心结论
- 在存在全局低灌注的情况下,去骨瓣减压骨窗下区域脑低灌注与创伤性脑损伤患者早期死亡相关。
- 需要进一步研究以确定将脑血流检查纳入重型创伤性脑损伤临床决策的价值。
研究设计与样本
- 研究纳入27例因创伤性脑损伤行去骨瓣减压术(清除占位病变和/或缓解难治性颅内高压)后接受氙增强CT脑血流检查的患者。
- 记录去骨瓣减压术前及氙增强CT检查时的脑血流动力学参数,测量术后全局及区域皮质脑血流,评估脑血流与脑血流动力学及早期临床结局的关联。
主要发现
- 88.9%的患者初始格拉斯哥昏迷评分≤8分,从受伤至去骨瓣减压手术的中位时间为9小时。
- 多数患者(n=18,66.7%)在24小时内接受初次去骨瓣减压手术,6例患者在出院时死亡。
- 氙增强CT脑血流检查在去骨瓣减压术后中位51小时进行,术后全局脑血流均值为49.9±21.3 ml/100 g/min,骨窗下皮质脑血流均值为46.0±21.7 ml/100 g/min。
- 出院时死亡患者骨窗下皮质脑血流显著低于存活患者(30.1±22.9 vs 50.6±19.6 ml/100 g/min;p=0.039),其全局脑血流(36.7±23.4 vs 53.7±19.7 ml/100 g/min;p=0.09)、同侧半球脑血流(33.3±27.2 vs 51.8±19.7 ml/100 g/min;p=0.07)和对侧半球脑血流(36.7±19.2 vs 55.2±21.9 ml/100 g/min;p=0.08)较低,但这些差异未达统计学显著。
- 死亡患者脑灌注压显著低于存活患者(52±17.4 vs 75.3±10.9 mm Hg;p=0.001)。
局限性
- 需要进一步研究以确定将脑血流检查纳入重型创伤性脑损伤临床决策的价值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE Few studies have reported on changes in quantitative cerebral blood flow (CBF) after decompressive craniectomy and the impact of these measures on clinical outcome. The aim of the present study was to evaluate global and regional CBF patterns in relation to cerebral hemodynamic parameters in patients after decompressive craniectomy for traumatic brain injury (TBI). METHODS The authors studied clinical and imaging data of patients who underwent xenon-enhanced CT (XeCT) CBF studies after decompressive craniectomy for evacuation of a mass lesion and/or to relieve intractable intracranial hypertension. Cerebral hemodynamic parameters prior to decompressive craniectomy and at the time of the XeCT CBF study were recorded. Global and regional CBF after decompressive craniectomy was measured using XeCT. Regional cortical CBF was measured under the craniectomy defect as well as for each cerebral hemisphere. Associations between CBF, cerebral hemodynamics, and early clinical outcome were assessed. RESULTS Twenty-seven patients were included in this study. The majority of patients (88.9%) had an initial Glasgow Coma Scale score ≤ 8. The median time between injury and decompressive surgery was 9 hours. Primary decompressive surgery (within 24 hours) was performed in the majority of patients (n = 18, 66.7%). Six patients had died by the time of discharge. XeCT CBF studies were performed a median of 51 hours after decompressive surgery. The mean global CBF after decompressive craniectomy was 49.9 ± 21.3 ml/100 g/min. The mean cortical CBF under the craniectomy defect was 46.0 ± 21.7 ml/100 g/min. Patients who were dead at discharge had significantly lower postcraniectomy CBF under the craniectomy defect (30.1 ± 22.9 vs 50.6 ± 19.6 ml/100 g/min; p = 0.039). These patients also had lower global CBF (36.7 ± 23.4 vs 53.7 ± 19.7 ml/100 g/min; p = 0.09), as well as lower CBF for the ipsilateral (33.3 ± 27.2 vs 51.8 ± 19.7 ml/100 g/min; p = 0.07) and contralateral (36.7 ± 19.2 vs 55.2 ± 21.9 ml/100 g/min; p = 0.08) hemispheres, but these differences were not statistically significant. The patients who died also had significantly lower cerebral perfusion pressure (52 ± 17.4 vs 75.3 ± 10.9 mm Hg; p = 0.001). CONCLUSIONS In the presence of global hypoperfusion, regional cerebral hypoperfusion under the craniectomy defect is associated with early mortality in patients with TBI. Further study is needed to determine the value of incorporating CBF studies into clinical decision making for severe traumatic brain injury.
引用
- Vedantam A, Robertson CS, Gopinath SP, et al. Quantitative cerebral blood flow using xenon-enhanced CT after decompressive craniectomy in traumatic brain injury. J Neurosurg. 2017. PMID: 29027859. doi:10.3171/2017.4.JNS163036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。