文献速递小儿神经外科与脑积水神经重症

脑实质内颅内压监测用于脑积水和脑脊液疾病

Intraparenchymal intracranial pressure monitoring for hydrocephalus and cerebrospinal fluid disorders.
PubMed 文献 · Acta Neurochir (Wien) · 2017-08-10

本回顾性研究分析了198例因疑似脑积水和脑脊液疾病接受择期脑实质内颅内压监测的神经外科初治患者的颅内压中位数和脉冲振幅记录,按全体、日间和夜间分别提取。主成分分析提示脉冲振幅解释61.4%的方差,颅内压解释33.0%;不同诊断组间脉冲振幅和颅内压存在显著差异。

要点

  • 主成分分析中脉冲振幅解释61.4%的数据方差,颅内压解释33.0%。
  • 保守治疗组与Chiari/脊髓空洞、IIH、NPH/LOVA组间脉冲振幅存在显著差异。
  • 保守治疗组与高压、IIH、低压组间颅内压存在显著差异。

核心结论

  • 本研究为不同诊断组的脑脊液流体动力学障碍提供了见解。
  • 研究强调分析日间和夜间分层的脉冲振幅和颅内压中位数记录均有价值。

研究设计与样本

  • 回顾性分析前瞻性收集的数据库,纳入因疑似脑积水和脑脊液疾病接受择期颅内压监测的神经外科初治患者。
  • 共识别198例患者,分属6个不同诊断组,每组n=21-47。
  • 提取颅内压和脉冲振幅中位数(全体、日间和夜间),行主成分分析,并进行探索性比较和相关性分析。

主要发现

  • 主成分分析提示两个主要因子解释数据散布,其中61.4%的方差主要由脉冲振幅决定,33.0%由颅内压记录决定。
  • 脉冲振幅在保守治疗组与Chiari/脊髓空洞组、IIH组、NPH/LOVA组之间存在显著差异。
  • 颅内压在保守治疗组与高压组、IIH组、低压组之间存在显著差异。
  • 颅内压与脉冲振幅的相关性在不同诊断组中呈现一些趋势。
  • 颅内压、脉冲振幅与年龄的相关性显示,随年龄增长颅内压降低而脉冲振幅升高。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Elective intraparenchymal intracranial pressure (ICP) monitoring is useful for the diagnosis and treatment of hydrocephalus and cerebrospinal fluid (CSF) disorders. This retrospective study analyzes median ICP and pulse amplitude (PA) recordings in neurosurgically naïve patients undergoing elective ICP monitoring for suspected CSF disorders. METHODS: Retrospective review of prospectively collated database of neurosurgically naïve patients undergoing elective ICP monitoring for suspected hydrocephalus and CSF disorders. Following extraction of the median ICP and PA values (separated into all, day and night time recordings), principal component analysis (PCA) was performed to identify the principal factors determining the spread of the data. Exploratory comparisons and correlations of ICP and PA values were explored, including by post hoc diagnostic groupings and age. RESULTS: A total of 198 patients were identified in six distinct diagnostic groups (n = 21-47 in each). The PCA suggested that there were two main factors accounting for the spread in the data, with 61.4% of the variance determined largely by the PA and 33.0% by the ICP recordings. Exploratory comparisons of PA and ICP between the diagnostic groups showed significant differences between the groups. Specifically, significant differences were observed in PA between a group managed conservatively and the Chiari/syrinx, IIH, and NPH/LOVA groups and in the ICP between the conservatively managed group and high-pressure, IIH, and low-pressure groups. Correlations between ICP and PA revealed some interesting trends in the different diagnostic groups and correlations between ICP, PA, and age revealed a decreasing ICP and increasing PA with age. CONCLUSIONS: This study provides insights into hydrodynamic disturbances in different diagnostic groups of patients with CSF hydrodynamic disorders. It highlights the utility of analyzing both median PA and ICP recordings, stratified into day and night time recordings.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Chari A, Dasgupta D, Smedley A, et al. Intraparenchymal intracranial pressure monitoring for hydrocephalus and cerebrospinal fluid disorders. Acta Neurochir (Wien). 2017. PMID: 28799016. doi:10.1007/s00701-017-3281-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。