先天性偏瘫与难治性癫痫患者切除性癫痫手术中脑定位所定义的皮质脊髓投射模式
一例34岁男性先天性脑病变导致偏瘫并自幼癫痫发作,近2年发展为难治性癫痫并接受切除性癫痫手术。术中采用创新神经电生理监测技术,同时记录双侧肢体复合肌肉动作电位以确定皮质脊髓投射模式,先于开颅前经颅刺激识别投射模式,开颅后直接皮层刺激精准界定非 eloquent 区,指导切除并成功完成手术目标。作者认为该技术简单、无需患者配合,有望替代常规术前功能磁共振和经颅磁刺激。
要点
- 先天性偏瘫合并难治性癫痫患者,切除性手术中采用双侧肢体同时记录复合肌肉动作电位的神经电生理监测技术。
- 开颅前经颅刺激识别皮质脊髓投射模式,开颅后直接皮层刺激精准界定非 eloquent 区并指导切除。
- 作者认为该技术简单、无需患者配合,有望替代常规术前功能磁共振和经颅磁刺激,尤其适用于年轻患者。
核心结论
- 作者认为该术中神经电生理监测技术简单且无需患者配合,有望替代常规术前功能磁共振和经颅磁刺激,尤其适用于年轻患者,并可提高手术安全性及帮助预测功能结局。
研究设计与样本
- 病例报告:一例34岁男性先天性脑病变导致偏瘫并自幼癫痫发作、近2年发展为难治性癫痫的患者,接受切除性癫痫手术。
主要发现
- 术中同时记录双侧肢体复合肌肉动作电位,而非仅记录对侧肌肉,以确定皮质脊髓投射模式。
- 开颅前经颅刺激双侧大脑半球,开颅后对病变侧半球行直接皮层刺激,整合两者先识别皮质脊髓投射模式,再精准界定非 eloquent 区并指导切除。
临床怎么用
- 作者认为该技术有望替代常规术前功能磁共振和经颅磁刺激用于切除性癫痫手术,尤其适用于年轻患者。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Congenital or early-onset brain structural lesions often cause contralateral hemiparesis, cognitive deficits, developmental delays, and seizures. Seizure is the most debilitating condition, as it greatly impairs quality of life in both the affected individuals and their caregivers and prevents them from active social participation. CASE DESCRIPTION: A 34-year-old man with hemiparesis and early-onset seizures since childhood owing to a congenital brain lesion developed intractable seizures in the last 2 years and was subsequently admitted for resective epileptic surgery. During the operation, we employed an innovative intraoperative neurophysiologic monitoring technique. In contrast to routine application for transcranial stimulation, we recorded compound muscle action potentials over the bilateral limb muscles simultaneously, instead of over the contralateral muscles only, to determine the patterns of the corticospinal projections. Transcranial stimulation over the bilateral hemispheres was applied before craniotomy, and direct cortical stimulation over the lesioned hemisphere was applied after craniotomy. By integrating both approaches, we could first identify the pattern of corticospinal projections before craniotomy and then accurately define the noneloquent area, which guided the resection to successfully accomplish the surgical goal. CONCLUSIONS: This technique is simple because no patient participation is required. We believe that it has the potential to replace conventional preoperative functional magnetic resonance imaging and transcranial magnetic stimulation in resective epilepsy surgery, particularly for young patients. Not only can it improve the safety of surgical procedures, but also it can help predict functional outcome.
引用
- Yang CY, Chen HH, Chen C, et al. Pattern of Corticospinal Projections Defined by Brain Mapping During Resective Epilepsy Surgery in a Patient with Congenital Hemiparesis and Intractable Epilepsy. World Neurosurg. 2017. PMID: 28842233. doi:10.1016/j.wneu.2017.08.071
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。