文献速递功能神经外科

微电极记录引导与术中磁共振成像引导的丘脑底核脑深部电刺激术治疗帕金森病的比较:1年随访研究

Microelectrode Recording-Guided Versus Intraoperative Magnetic Resonance Imaging-Guided Subthalamic Nucleus Deep Brain Stimulation Surgery for Parkinson Disease: A 1-Year Follow-Up Study.
PubMed 文献 · World Neurosurg · 2017-08-24

本研究回顾性比较了本机构76例微电极记录引导(A组)与61例术中磁共振成像引导(B组)的丘脑底核脑深部电刺激术帕金森病患者,1年随访时两组在电极偏移、UPDRS-III评分改善、PDQ-39评分改善、MMSE评分改善及左旋多巴等效日剂量降低方面均无显著差异,结论为两种技术均能有效确保电极放置,但无优劣之分。

要点

  • 微电极记录引导与术中磁共振成像引导的丘脑底核脑深部电刺激术在1年随访时疗效无显著差异。
  • 两组电极偏移在x、y、z轴均无显著差异(P值分别为0.34、0.26、0.41)。
  • 停药12小时后UPDRS-III评分改善率A组66.3%±13.5% vs B组64.8%±12.7%(P=0.24)。

核心结论

  • 微电极记录和术中磁共振成像均是确保脑深部电刺激术中电极充分放置的有效方法,但至少就1年随访结果而言,两种技术之间无优劣之分。

研究设计与样本

  • 本研究为回顾性比较研究,比较了本机构接受微电极记录引导(A组,n=76)和术中磁共振成像引导(B组,n=61)丘脑底核脑深部电刺激术的帕金森病患者。

主要发现

  • 电极偏移均值:A组x=1.1±0.2 mm、y=1.3±0.3 mm、z=2.1±0.5 mm;B组x=1.3±0.4 mm、y=1.2±0.2 mm、z=2.5±0.7 mm;两组x、y、z轴差异均无统计学意义(P=0.34、P=0.26、P=0.41)。
  • 1年随访时停药12小时后,UPDRS-III评分改善率A组66.3%±13.5% vs B组64.8%±12.7%(P=0.24)。
  • PDQ-39汇总指数评分改善率A组49.7%±14.3% vs B组44.1%±12.7%(P=0.16)。
  • MMSE评分改善率A组4.2%±2.1% vs B组11.1%±3.2%(P=0.43);左旋多巴等效日剂量降低率A组48.7%±10.1% vs B组56.9%±12.0%(P=0.32)。

临床怎么用

  • 原文结论认为微电极记录和术中磁共振成像均为确保脑深部电刺激术中电极充分放置的有效方法,但两者无优劣之分。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Microelectrode recording (MER) and intraoperative magnetic resonance imaging (iMRI) have been used in deep brain stimulation surgery for Parkinson disease (PD), but comparative methodology is lacking. Therefore, we compared the 1-year follow-up outcomes of MER-guided and iMRI-guided subthalamic nucleus (STN) deep brain stimulation (DBS) surgery in PD patients. METHODS: We conducted a review comparing PD patients who underwent MER-guided (n = 76, group A) and iMRI-guided STN DBS surgery (n = 61, group B) in our institution. Pre- and postoperative assessments included Unified Parkinson's Disease Rating Scale-III (UPDRS-III) score, Parkinson's Disease Questionnaire (PDQ-39), Mini-Mental State Examination (MMSE), levodopa equivalent daily doses (LEDDs), and magnetic resonance images. RESULTS: The mean magnitudes of electrode discrepancy were x = 1.1 ± 0.2 mm, y = 1.3 ± 0.3 mm, and z = 2.1 ± 0.5 mm in group A and x = 1.3 ± 0.4 mm, y = 1.2 ± 0.2 mm, and z = 2.5 ± 0.7 mm in group B. Significant differences were not found between 2 groups for x, y, or z (P = 0.34, P = 0.26, and P = 0.41, respectively). At 1 year, when levodopa was withdrawn for 12 hours, the UPDRS-III score improved by 66.3% ± 13.5% in group A and 64.8% ± 12.7% in group B (P = 0.24); the PDQ-39 summary index score improved by 49.7% ± 14.3% in group A and 44.1% ± 12.7% in group B (P = 0.16); the MMSE score improved by 4.2% ± 2.1% in group A and 11.1% ± 3.2% in group B (P = 0.43); and LEDDs decreased by 48.7% ± 10.1% in group A and 56.9% ± 12.0% in group B (P = 0.32). CONCLUSIONS: MER and iMRI both are effective ways to ensure adequate electrode placement in DBS surgery, but there is no superiority between both techniques, at least in terms of 1-year follow-up outcomes.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Liu X, Zhang J, Fu K, et al. Microelectrode Recording-Guided Versus Intraoperative Magnetic Resonance Imaging-Guided Subthalamic Nucleus Deep Brain Stimulation Surgery for Parkinson Disease: A 1-Year Follow-Up Study. World Neurosurg. 2017. PMID: 28842228. doi:10.1016/j.wneu.2017.08.077

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。