文献速递神经肿瘤

残余无功能垂体腺瘤缩小的可能性与病变血供模式相关

The Likelihood of Remnant Nonfunctioning Pituitary Adenomas Shrinking Is Associated with the Lesion's Blood Supply Pattern.
PubMed 文献 · World Neurosurg · 2017-08-02

本研究纳入31例患者的37个残余无功能垂体腺瘤,术前行动态3.0T MRI评估血供,术后1-2周及3-6个月复查MRI。37个残余瘤中15个(40.5%)在术后3-6个月缩小,头侧位置和上升型血供模式为缩小的阳性预测因素,血供丰富者未见自发缩小。

要点

  • 37个残余无功能垂体腺瘤中15个(40.5%)在术后3-6个月随访MRI显示缩小。
  • 头侧残余瘤较尾侧更易缩小(P < 0.0001)。
  • 上升型血供模式为肿瘤缩小的阳性预测因素(P = 0.002),血供丰富者未见自发缩小(P < 0.0001)。

核心结论

  • 术前动态MRI评估残余无功能垂体腺瘤血供及残余瘤位置,可能有助于预测术后肿瘤缩小。

研究设计与样本

  • 研究纳入31例在Yamagata大学医院神经外科治疗的患者的37个残余肿瘤,术前行动态3.0T MRI评估肿瘤动脉血供,行内镜下经蝶手术及术中1.5T MRI,术后1-2周和3-6个月复查MRI。

主要发现

  • 37个残余肿瘤中15个(40.5%)在术后3-6个月随访MRI显示缩小。
  • 残余肿瘤位于头侧21例、尾侧16例,头侧残余肿瘤更易缩小(P < 0.0001)。
  • 按血供模式分为3组:上升型23个、下降型6个、单相型2个,上升型血供模式为肿瘤缩小的阳性预测因素(P = 0.002)。
  • 血供丰富的残余肿瘤未见自发缩小(P < 0.0001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Nonfunctioning pituitary adenomas (NFPA) often shrink after transsphenoidal surgery. However, little is known about the predictors of spontaneous NFPA regression. The aim of this study was to determine whether the blood supply pattern of remnant NFPA lesions was associated with the likelihood of such lesions shrinking. METHODS: A total of 37 remnant tumors in 31 patients who were treated at the Department of Neurosurgery, Yamagata University Hospital, were included in this study. All patients underwent preoperative dynamic 3.0T magnetic resonance imaging (MRI) to evaluate their tumors' arterial blood supplies, followed by endoscopic transsphenoidal surgery and intraoperative 1.5T MRI. Follow-up MRI scans were obtained at 1-2 weeks and 3-6 postoperative months. RESULTS: We detected tumor shrinkage in 15 of 37 (40.5%) remnant tumors on follow-up MRI scans obtained at 3-6 postoperative months. Remnant tumors were found in rostral and caudal locations in 21 and 16 cases, respectively. Rostral remnant tumors were significantly more likely to shrink (P < 0.0001). The tumors were classified into 3 groups according to their blood supply patterns (23 ascending, 6 descending, and 2 monophasic). The ascending blood supply pattern was found to be a positive predictor of tumor shrinkage (P = 0.002). Furthermore, no remnant tumors with rich blood supplies underwent spontaneous regression (P < 0.0001). CONCLUSIONS: Evaluations of the blood supplies of remnant NFPA via preoperative dynamic MRI and the locations of the remnant tumors could be useful for predicting postoperative tumor shrinkage.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Ito M, Kuge A, Matsuda KI, et al. The Likelihood of Remnant Nonfunctioning Pituitary Adenomas Shrinking Is Associated with the Lesion's Blood Supply Pattern. World Neurosurg. 2017. PMID: 28780404. doi:10.1016/j.wneu.2017.07.141

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。