文献速递脑血管病外科

血流导向装置治疗串联颅内动脉瘤

Flow Diverter Treatment of Tandem Intracranial Aneurysms.
PubMed 文献 · World Neurosurg · 2017-08-03

回顾性分析20例女性串联颅内动脉瘤患者,平均年龄60±12岁,共22次手术、47个动脉瘤,均位于颅内颈内动脉。82%的病例使用单枚支架、无辅助弹簧圈栓塞,无术中并发症;随访40个动脉瘤中34个(85%)完全闭塞,19/20(95%)患者改良Rankin量表评分为0-2。作者认为血流导向装置技术上可行、安全有效,但需更大规模研究证实。

要点

  • 20例女性患者、47个串联颅内动脉瘤均位于颅内颈内动脉,全部一次手术成功治疗。
  • 82%的病例使用单枚支架且无辅助弹簧圈栓塞,无术中并发症,3例出现轻度短暂神经症状。
  • 随访40个动脉瘤中34个(85%)完全闭塞,19/20(95%)患者改良Rankin量表评分为0-2。

核心结论

  • 作者认为血流导向装置治疗串联颅内动脉瘤技术上可行、安全有效,可能优于传统血管内或手术治疗方式;需要更大规模研究证实这些发现。

研究设计与样本

  • 回顾性分析接受血流导向装置治疗的串联颅内动脉瘤患者,共纳入20例女性患者,平均年龄60±12岁。

主要发现

  • 共22次手术、47个动脉瘤,均位于颅内颈内动脉;3例为既往血管内治疗后的动脉瘤复发。
  • 所有动脉瘤均在1次手术中成功治疗;大多数(82%)病例使用单枚支架,无辅助弹簧圈栓塞。
  • 无术中并发症;3例患者术后出现轻度短暂神经症状,无长期神经功能缺损。
  • 18/20(90%)患者有数字减影血管造影和/或增强磁共振血管成像随访,平均随访18.8±11.2个月;随访的40个动脉瘤中34个(85%)完全闭塞。
  • 20/20(100%)患者有临床随访,19/20(95%)改良Rankin量表评分为0-2;治疗后无动脉瘤破裂,末次随访时无患者需要再治疗。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文结论指出需要更大规模研究证实这些发现。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess technical success and clinical and imaging outcomes of flow diversion (FD) treatment of multiple, tandem intracranial aneurysms. METHODS: Retrospective analysis was performed of patients treated with FD for tandem intracranial aneurysms. RESULTS: Twenty female patients with a mean (±SD) age of 60 (±12) years were included. One patient was treated after subarachnoid hemorrhage. In 22 separate procedures, 47 aneurysms, all located in the intracranial internal carotid artery, were treated. In 3 cases, treatment was performed for aneurysm recurrence after previous endovascular treatment. All aneurysms were successfully treated in 1 session. A single stent was used in most (82%) cases, with no adjunctive coiling. There were no intraprocedural complications. Three patients experienced mild, transient neurologic symptoms after the procedure with no long-term neurologic deficits. Follow-up imaging with digital subtraction angiography and/or contrast-enhanced magnetic resonance angiography was available in 18/20 (90%) patients at an average (±SD) of 18.8 (±11.2) months. Of 40 aneurysms with follow-up imaging, 34 (85%) were completely occluded. Clinical follow-up, available in 20/20 (100%) patients, showed that 19/20 (95%) achieved a modified Rankin Scale score of 0-2. There were no cases of aneurysm rupture after treatment, and no patients required retreatment at last available follow-up. CONCLUSIONS: FD appears technically feasible, safe, and effective for treatment of tandem intracranial aneurysms, with potential advantages over traditional endovascular or surgical treatment modalities. Larger studies are needed to confirm these findings.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. John S, Bain M, Cerejo R, et al. Flow Diverter Treatment of Tandem Intracranial Aneurysms. World Neurosurg. 2017. PMID: 28782689. doi:10.1016/j.wneu.2017.07.146

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。