睡眠下机器人辅助丘脑底核电极植入提供与清醒手术相同的临床改善和治疗窗
23例帕金森病患者接受机器人辅助双侧丘脑底核脑深部电刺激电极植入,13例全麻下仅评估副作用,10例局麻下全面评估。术后12个月治疗窗两组相似(局麻组2.06±0.53 V vs 全麻组2.28±0.99 V,P=0.32),短期UPDRS III运动评分改善程度两组无显著差异。结论认为睡眠下机器人辅助手术与清醒手术产生相同的运动结果和治疗窗。
要点
- 全麻组与局麻组术后12个月治疗窗相似(2.28±0.99 V vs 2.06±0.53 V,P=0.32)。
- 短期「停药开刺激」UPDRS III评分改善全麻组49% vs 局麻组40.3%(P=0.336)。
- 短期「开刺激用药」UPDRS III评分改善全麻组70.7% vs 局麻组57%(P=0.36)。
核心结论
- 睡眠下机器人辅助丘脑底核脑深部电刺激电极植入(准确识别丘脑底核并定位电极)产生与清醒手术相同的运动结果和治疗窗。
研究设计与样本
- 23例帕金森病患者接受机器人辅助双侧丘脑底核脑深部电刺激电极植入,其中13例全麻下仅评估副作用,10例局麻下全面评估。
主要发现
- 术后12个月治疗窗局麻组为2.06±0.53 V,全麻组为2.28±0.99 V,两组相似(P=0.32)。
- 短期「停药开刺激」UPDRS III评分局麻组下降40.3%,全麻组下降49%,两组下降程度相似(P=0.336)。
- 短期「开刺激用药」UPDRS III评分局麻组下降57%,全麻组下降70.7%,两组下降程度相似(P=0.36)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To study the impact of not performing awake clinical evaluation during the robot-assisted implantation of subthalamic nucleus deep brain stimulation (STN-DBS) electrodes on the stimulation parameters and clinical outcomes in patients with Parkinson disease (PD). METHODS: A total of 23 patients with PD underwent robot-assisted surgery for the bilateral implantation of STN-DBS electrodes. Thirteen patients received general anesthesia (GA) and a limited intraoperative evaluation (side effects only), and the other 10 patients received local anesthesia (LA) and a full evaluation. The primary endpoint was the therapeutic window (TW), defined as the difference between the mean voltage threshold for motor improvement and the mean voltage threshold for side effects in the active contacts at 12 months after surgery. Motor scores were measured as well. RESULTS: The TW was similar in the LA and GA groups, with mean ± standard deviation values of 2.06 ± 0.53 V and 2.28 ± 0.99 V, respectively (P = 0.32). In the short term, the Unified Parkinson Disease Rating Scale (UPDRS) III score in the "off-drug, on-stim" condition fell to a similar extent in the LA and GA groups (by 40.3% and 49%, respectively; P = 0.336), as did the UPDRS III score in the "on-stim, on-drug" condition (by 57% and 70.7%, respectively; P = 0.36). CONCLUSIONS: Asleep, robot-assisted implantation of STN-DBS electrodes (with accurate identification of the STN and positioning of the DBS lead) produced the same motor results and TW as awake surgery.
引用
- Lefranc M, Zouitina Y, Tir M, et al. Asleep Robot-Assisted Surgery for the Implantation of Subthalamic Electrodes Provides the Same Clinical Improvement and Therapeutic Window as Awake Surgery. World Neurosurg. 2017. PMID: 28735132. doi:10.1016/j.wneu.2017.07.047